A. Activate LAL. This may be done in one of two ways: First, by 

moving the front panel toggle switch DOWN to "LAL". Second, by 
raising pin 18 on the interface. (NOTE:  Make sure DIP switch 
SW1-8 is OFF). Once LAL is activated, the Model 1140 transmit 
output is connected to its own receiver. The "test" LED should be lit. 
 

B. Verify that the data terminal equipment is operating properly 

and can be used for a test. If a fault is indicated, call a technician or 
replace the unit. 
 

C. Perform a BER (bit error rate) test on each unit. If the BER 

test equipment indicates no faults, but the data terminal indicates a 
fault, follow the manufacturer's checkout procedures for the data 
terminal. Also, check the interface cable between the terminal and 
the Model 1140. 

 

5.2.2 REMOTE DIGITAL LOOPBACK (RDL) 

The Remote Digital Loopback (RDL) test checks the 

performance of both the local and remote Model 1140s, and the 
communication link between them. Any characters sent to the 
remote Model 1140 in this test mode will be returned back to the 
originating device. For example, characters typed on the keyboard of 
the local terminal will appear on the local terminal screen after 
having been passed to the remote Model 1140 and looped back. To 
perform an RDL test, follow these steps: 

 
A. Activate RDL. This may be done in two ways: first, by moving 

the front panel toggle switch UP to "RDL". Second, by raising pin 21 
on the interface. (NOTE:  Make sure SW1-8 is OFF). 
 

B. Perform a BER (bit error rate) test on the system. 

 

C. If the BER test equipment indicates a fault, and the Local 

Analog Loopback test was successful for both Model 1140s, you 
may have a problem with the twisted pair line between the modems. 
You should then check the fiber line for proper connections and 
continuity. 

Содержание 1140

Страница 1: ...ith V 54 Diagnostics Model 1140 Documentation Number 11401198 B B Electronics Mfg Co Inc 707 Dayton Road P O Box 1040 Ottawa IL 61350 PH 815 433 5100 FAX 815 433 5105 Internet http www bb elec com ord...

Страница 2: ...ough S1 4 Data Rate Setting 6 S1 5 and S1 6 Clock Source 6 S1 7 Asynchronous Synchronous Mode 6 S1 8 Carrier Control Method 7 3 3 CONFIGURATION SWITCH SET S2 7 S2 1 and S2 2 Word Length 7 S2 3 Extende...

Страница 3: ...lation or use of this product shall be deemed an acceptance of these terms by the user 1 1 RADIO AND TV INTERFERENCE The Model 1140 generates and uses radio frequency energy and if not installed and u...

Страница 4: ...must have a Return Materials Authorization number on the outside of the shipping container This number may be obtained from B B Electronics Customer Service at 815 433 5100 Packages received without...

Страница 5: ...DESCRIPTION The B B Model 1140 miniature dual fiber optic modem brings fiber to the desktop Combining the inviolability of fiber with the troubleshooting capabilities of V 52 and V 54 diagnostics the...

Страница 6: ...uses a unique set of 16 external mini DIP switches that allow configuration to an extremely wide range of applications These 16 DIP switches are grouped in two eight switch sets and are externally acc...

Страница 7: ...d to as S1 and S2 As Figure 2 shows the orientation of all DIP switches is the same with respect to ON and OFF positions Figure 2 Close up of DIP switches showing ON and OFF positions 3 2 CONFIGURATIO...

Страница 8: ...4 8 Kbps Off On Off On 7 2 Kbps On Off Off On 9 6 Kbps Off Off Off On 14 4 Kbps On On On Off 19 2 Kbps Off On On Off 28 8 Kbps On On Off Off 38 4 Kbps Off On Off Off 57 6 Kbps S1 5 and S1 6 Clock Sou...

Страница 9: ...ltipoint and or hardware handshaking applications S1 8 Setting Off Constantly On On Switched Carrier 3 3 CONFIGURATION SWITCH SET S2 The DIP switches on S2 set word length extended signaling rate RTS...

Страница 10: ...1140 will tolerate S2 3 Setting Off 2 5 to 1 Basic On 2 5 to 2 3 Extended S2 4 and S2 5 RTS CTS Delay The combined settings for switches S2 4 and S2 5 determine the amount of delay between the time t...

Страница 11: ...r panel Figure 5 Close up of ST and SMA connections 4 1 FIBER CONNECTIONS The Model 1140 short range modems are designed to work in pairs You will need one at each end of a dual fiber cable This cable...

Страница 12: ...uate the condition of the modems and the communication link These tests can be activated physically from the front panel or via the interface NOTE V 54 test modes on the Model 1140 are available for p...

Страница 13: ...the terminal and the Model 1140 5 2 2 REMOTE DIGITAL LOOPBACK RDL The Remote Digital Loopback RDL test checks the performance of both the local and remote Model 1140s and the communication link betwee...

Страница 14: ...unit If any errors are present the receiving modem s red Error LED will blink sporadically NOTE For this test to function the 511 switch on both Model 1140s must be on 2 If the test indicates no error...

Страница 15: ...ntinuous fiber RTS CTS Delay Switch selectable No delay 9 0 mS 79 5 mS Receiver Sensitivity 45 dBm Coupled Power Output 30 to 36 dBm Optic Wavelength 850 nm LED Indicators Carrier Detect and Fiber Opt...

Страница 16: ...14 Documentation Number 11401198 Manual B B Electronics PO Box 1040 Ottawa IL 61350 PH 815 433 5100 FAX 815 433 5105 APPENDIX B PIN CONFIGURATIONS...

Отзывы: