BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-3070 USA
P: 1-800-525-0758
F: 1-800-624-3925
Document # P46050 rev. -
© Copyright
BAND-IT-IDEX, Inc. 2008
All rights reserved
www.BAND-IT-IDEX.com
Page 2 of 4
GRC001 Hand Tool
JR Adapters: The JR adapters (J00169 and J05069 heavy duty) are used with the BAND-IT GRC001 tool when
BAND-IT JR. preformed clamps are used.
C04388 Close Quarter Tension Nut: In cramped quarters, use instead of tool tension handle.
NOTE: See general catalog or web site for instructions and ordering information.
Gripper Cleaning Instructions:
Cleaning and
Accessories
1. Remove gripper. Align gripper pin
hole with notch in tool frame. Using a
punch and hammer, punch pin out of
slide block.
2. Using a wire brush, clean all
foreign matter from teeth.
Scru-Lokt Buckles:
1. The BAND-IT Scru-Lokt clamp,
using the Scru-Lokt buckle, is
applied in exactly the same way as
the BAND-IT clamp except that the
tool is not rolled over.
Tool Accessories:
3. Where stub of band is left
for Scru-Lokt clamp, it may be
folded under as shown.
2. After tension is applied, insert set screw in
Scru-Lokt buckle and tighten. To permit
taking up Scru-Lokt clamp, or to re-use, a 3
inch (7.5 cm) stub should be left so that tool
will be able to re-grip band later.
3. Replace pin. Gripper spring must be
seated in tension screw hole. Align
gripper hole with slide block hole, insert
pin in hole and hammer pin in place.