4. Installation & Operation 
 

 

4.1  Connecting Lines 

 

1) Connecting Air-pressure lines 

-

  Straightly insert the tube into the air 

fitting until it gets installed inside 

-

  Valve open line(A) is connected to the 

“open” port on the TAD-200V(controller). 

-

  Valve close line(B) is connected to the 

“air out” port on the TAD-
200V(controller). 

-

  Pull the tube gently in order to make 

sure that it is safe. 

2) Connecting Fluid Line 

-

  The inlet of Fluid line(C) fits in PT 1/8” 

line. 

3) Caution 

-

  When you cut the tube, make the 

severed side a right angled out and the 
use of a tube-cutter is recommended. 

-

  Install the fluid line in oblique with the air 

line in order to minimize the intervention. 
 

4.2    Operation 

 

1) Preparing to use 

-

  Open the fluid line and valve open air 

line(A) of the valve. 

-

  Keep dispensing until the consistent 

drippings in order to eleminates the air 
in the valve. 

-

  And then stop dispensing. 

2) Control of the dispensing volume 

-

  Adjust the pressure of fluid inlet. 

-

  Change the nozzle tip(D) to be 

compatible to preventing from air 
bubbles. 

 

Содержание BV-302

Страница 1: ...EQUIPMENT User Manual BV 302 Needle off type dispensing valve...

Страница 2: ...3 2 Specification 4 3 Principle 4 4 Installation Operation 5 4 1 Connecting lines 5 4 2 Operation 5 5 Maintenance Cleaning 6 5 1 Storing after use 6 5 2 Check items while operating 6 5 3 Exploded vie...

Страница 3: ...zed alteration of parts and overuse it may cause a danger by exploding or leaking explosion or leakage may occur Do not make any kind of unauthorized alterations We are not responsible for any repairs...

Страница 4: ...pressure forces the internal piston to move down and the needle closes stopping the fluid flow and being pushed a slight amount of fluid The amount of fluid dispensed will depend on the time the valve...

Страница 5: ...et of Fluid line C fits in PT 1 8 line 3 Caution When you cut the tube make the severed side a right angled out and the use of a tube cutter is recommended Install the fluid line in oblique with the a...

Страница 6: ...k other connecting appliances that are properly turned off Be sure that end of nozzle is not clogged with hardened fluid 5 3 Exploded view The user s arbitrary disassembly is not recommended 1 Needle...

Страница 7: ...ir into valve on off line The fluid is cured Clean the valve see chapter 5 4 Pressure the fluid reservoir The fluid does not supply Supply the fluid No dispensing The controller is turned off Turn on...

Страница 8: ...8 7 Outside view...

Отзывы: