background image

555 M1 05 C

04-09-2008

Page 2

CAUTION

•  Trained personnel may only perform installation, initial start-up and maintenance. 

All applicable European and national regulations regarding installation of electrical equipment must be adhered to. 

•  The device may only be connected to supply power complying with the specifications included in the technical data and on the

serial plate.

•  The device must be disconnected from all sources of power during installation and maintenance work!

•  The device may only be operated under the conditions specified in the operating instructions!

DESCRIPTION

The MAXIMAT LWC-B leakage sensor (on floor detection) is used for leakage detection in catch basins and catch spaces. 
It is equipped with three different output circuits:

•  A binary output for controlling a coupling relay or the digital input at a PLC 
•  A 0 to 20 mA current output for controlling an analog input channel, e.g. a programmed logic controller (PLC) 
•  Self-monitoring measuring circuit in combination with the MAXIMAT SHR C... measuring transducer with a 2 wires connection. 

TECHNICAL FEATURES

Supply power: 

24 V DC ± 10% 

(power supply with current limiting or 250 mA fuse recommended) 

Connected load: 

Approx. 3 W 

Ambient temperature: 

-20 to +60°C 

Outputs: 

+DO / -DO 

NPN max. 30 mA / max. 24 V DC 

+AO / -AO 

0 to 20 mA

Measuring circuit for use with SHR C...

Cable inductance: 

Maximum approx. 5 mH 

Cable capacitance: 

Maximum approx. 0.5 μF 

Measuring circuit cable:

Maximal length = 300 m 

Wire cross-section: 

Minimum 0.5 mm

2

DIBT Approval 

Approval N° Z-65.40-316 for overfill sensors and leakage sensors in accordance with WHG §19 

Note:

The accompanying “General Building Supervisory Approval N° Z-65.40-316” is an integral part of the operating instructions and all
stipulations contained therein must be adhered to! 

CE mark: 

In accordance with low-voltage directive (73/23/EWG), EMC directive (89/336/EWG) and standards EN 50 082-2:1995 & EN 55

011 (class A):1998. 