Bamo BSM 501 Скачать руководство пользователя страница 2

Safety Precautions 

• Assembly, commissioning and servicing may only be performed by specialist personnel! 

Applicable European and national regulations for erection of electric systems must be complied with. 

• Connect the device only to voltage indicated in the technical data and on the nameplate. 
• In case of assembly or maintenance work, the device must be disconnected from all currents! 
• Operate the device only under the conditions defined in the operating instructions! 

1 - PRINCIPLE

The magnetic floats or counter-weights drive a lever arm to establish a dry contact, operating on a micro-switch. When the actuator
passes in front the switch it changes the status and stay on until the float passes again. 
The level switch BSM 501 is working with all our floats and counter-weights designed for standard tube of diameter 32, 35 or 63
mm. The model BSM 515 is specifically designed for use with our by pass level indicator MAGTOP in stainless steel; not
convenient for plastic or carbon steel MAGTOP

2 - MOUNTING 

- The level switch BSM 501 fits directly the guiding tube of a level indicator with a collar or in stainless steel or in plastic. 
- Take care of its position on the tube to allow the easiest electrical wiring operation. 
- The cable plug must always point down. The BSM 501 could be fixed all along the float operating way. 
- Open the Din plug to connect the cable. 

- Terminals are 3; the status NO or NC of the contact depends of

the wiring, please see the drawing and consult the notes below. 

- Let the cable passes through the pressure gland. 

- Remount the Din plug, screwing tightly to assure the waterproof

protection. 

Notes 

- To have a contact when the level is increasing, connect the 

terminals 1 and 2 (Normally Open). 

- To have a contact when the level is decreasing, connect the 

terminals 2 and 3 (Normally Close). 

- When using a SFA, cable and pulley operated level indicator, use

the reverse logic as the counterweight is going down when the
level is increasing. 

- Always install the float with "TOP" sign upside. 

Page

2

585 M1 01 G

03-01-2008

3 - TECHNICAL FEATURES

Rated voltage: 

4 V...250 V AC, 4 V...30 V DC

Rated current: 

1 mA ... 3 A (AC or DC) 

Switching principle: 

Magnetic actuated micro switch 
with change over contact 

Minimal distance: 

40 mm between two switching points 

Max. cable cross section:  1.5 mm

2

Connector: 

3 poles cable plug acc. DIN 
EN 175301 with Pg terminal 

Ambient temperature: 

-20°C ... +90°C 

Material: Transparent 

polycarbonate 

Fitting: 

Stainless steel or plastic collar 

Housing: 

IP 65 acc. EN 60 529

CE labels: 

In accordance with low Voltage 
Guidelines 72/73/EEC, 
EMV Guidelines 89/336/EEC

 
 

 

 
 

Set magnet rocker to correct position before service 

by moving the float or counter weight inside its guiding tube.

Connection:

Contact position while float is in lower position 

PVC tube Ø 32 x 27

or

Glass tube Ø 35 x 29

Float

Counter weight

PVC tube Ø 63 x 57

Отзывы: