background image

 9

Ref No.

Description

Part no.

1

15 litre vessel

BPB1099

2

Non-return valve

BPB1086

3

500mm delivery pipe

BPB1087a

4

Pressure switch

BPB1074

5

1/4” 10 Bar relief valve

BPB1084

6

1/4”Male / 1/4”Male adaptor

BPB1078

7

1/4” Male/Female elbow

BPB1139

8

Filter regulator

BPB1080

9

Regulator gauge

BPB1077

10

On/off valve

BPB1079

Ref No.

Description

Part no.

11

Vessel pressure gauge

BPB1081

12

1/4” Male/Male/Female Tee piece

BPB1095

13

Drain tap

BPB1138

14

250mm drain tube

BPB0414

15

Inspection plug

BPB0243

16

Inspection plug seal

BPB0502

17

Rubber foot

BPB0247

MD 75/150V

1

3

5

6

7

8

9

10

11

13

12

14

15

16

17

2

4

Содержание MD150/500

Страница 1: ...ds Birmingham B7 5HT United Kingdom Tel 0121 322 2299 Fax 0121 322 2297 Email sales bambi air co uk www bambi air co uk MD R a n g e O p e r a t o r s H a n d b o o k Covering Models MD35 20 MD75 80 MD75 150 MD75 150V MD75 250 MD75 250V MD150 500 MD225 1000 ...

Страница 2: ...l mechanical or personnel hazards and will invalidate your warranty Bambi reserves the right to modify the contents of this operating booklet without notice and the information is in no way binding on the company Warranty Provided the operating instructions have been followed and the compressor has been properly maintained Bambi compressors are guaranteed against faulty workmanship for a period of...

Страница 3: ...6 compressor oil does not contain hazardous components and is not required to be labelled dangerous according to the Classification Packaging and Labelling of Dangerous Substances regulation CPL Regulation 1984 Siting The Compressor What you must do Provide adequate protection from the weather Site the compressor level in both planes As larger models are heavy ensure the surface has sufficient loa...

Страница 4: ...alidate your warranty Starting Stopping Plug the compressor into an outlet socket of nominal voltage and fitted with a 13amp fuse Note Model 225 1000 requires a dedicated 20 amp power supply Switch the compressor on using the red button on top of the pressure switch Pull knob up to switch on push down to switch off see fig 3 The compressor will start running and automatically switch off at the pre...

Страница 5: ...f Valve Ensure the air receiver is not pressurised Unscrew the knurled end of the pressure relief valve until an audible click is heard Retighten without using excessive force see fig 6 Technical The compressor has a maximum 50 duty cycle The motor must never be allowed to run continuously otherwise it will overheat and may become damaged Do not ignore air leaks All air connections must be leak fr...

Страница 6: ...ment Check pressure relief activation Above are to be considered minimum frequency Technical Specification Type 35 Pump Specification Voltage 220 240 110 Motor Kw Hp 0 37 0 5 0 44 0 5 Frequency Hz 50 60 Amps 2 4 6 Watts 340 446 Displacement l min 50 60 FAD 6 Bar 33 39 Type 75 Pump Specification Voltage 220 240 110 Motor Kw Hp 0 5 0 5 0 64 0 5 Frequency Hz 50 60 Amps 3 6 7 8 Watts 500 733 Displacem...

Страница 7: ...5 Capacitor Overload protector To pressure switch Start relay BLACK BROWN BLACK BLUE BLACK Wiring Diagram 75 Pump unit Wiring Diagram 35 Pump unit ...

Страница 8: ... Female Tee BPB1109 7 1 4 Male 1 4 Male adaptor BPB1078 8 Vessel pressure gauge BPB1081 9 200mm delivery pipe BPB1102 10 250mm drain tube BPB0414 Ref No Description Part no 11 Non return valve BPB1086 12 1 4 Male 1 4 Male adaptor BPB1078 13 1 4 Drain tap BPB1138 14 Pressure switch BPB1074 15 1 4 10 Bar relief valve BPB1084 16 Handle insert BPB0078 1 3 5 6 7 8 9 10 11 13 12 14 15 16 2 4 ...

Страница 9: ...255 6 Drain tap BPB1138 7 250mm drain tube BPB0414 8 Pressure switch BPB1074 9 1 4 10 Bar relief valve BPB1084 10 1 4 Male 1 4 Male adaptor BPB1078 Ref No Description Part no 11 1 4 Male Female elbow BPB1139 12 On off valve BPB1079 13 1 4 Male Male Female tee BPB1095 14 Filter regulator BPB1080 15 Regulator gauge BPB1077 16 Vessel pressure gauge BPB1081 17 200mm delivery pipe BPB1102 18 Non return...

Страница 10: ... Female Female tee BPB1109 7 Non return valve BPB1086 8 200mm Delivery pipe BPB1102 9 1 4 10 Bar relief valve BPB1084 10 Pressure switch BPB1074 11 1 4 Male 1 4 Male adaptor BPB1078 12 On off valve BPB1079 Ref No Description Part no 13 Filter regulator BPB1080 14 Regulator gauge BPB1077 15 Vessel pressure gauge BPB1081 16 1 4 Extension BPB0152 17 Drain tap BPB1138 18 250mm drain tube BPB0414 19 Bl...

Страница 11: ...BPB1078 7 1 4 Male Female elbow BPB1139 8 Filter regulator BPB1080 9 Regulator gauge BPB1077 10 On off valve BPB1079 Ref No Description Part no 11 Vessel pressure gauge BPB1081 12 1 4 Male Male Female Tee piece BPB1095 13 Drain tap BPB1138 14 250mm drain tube BPB0414 15 Inspection plug BPB0243 16 Inspection plug seal BPB0502 17 Rubber foot BPB0247 MD 75 150V 1 3 5 6 7 8 9 10 11 13 12 14 15 16 17 2...

Страница 12: ...4 10 Bar relief valve BPB1084 7 1 4 Male Female Female tee BPB1109 8 Handle insert BPB0076 9 Drain tap BPB1138 10 250mm drain tube BPB0414 11 Siphon tube BPB0029 12 Pressure switch BPB1074 Ref No Description Part no 13 1 4 Male 1 4 Male adaptor BPB1078 14 On off valve BPB1079 15 Filter regulator BPB1080 16 Regulator gauge BPB1077 17 Vessel pressure gauge BPB1081 18 1 4 Extension BPB0152 19 Wheel k...

Страница 13: ... 10 Bar relief valve BPB1084 6 1 4 Male 1 4 Male adaptor BPB1078 7 1 4 Male Female elbow BPB1139 8 Filter regulator BPB1080 9 Regulator gauge BPB1077 10 On off valve BPB1079 11 Vessel pressure gauge BPB1081 12 1 4 Male Male Female tee BPB1095 Ref No Description Part no 13 Drain tap BPB1138 14 250mm drain tube BPB0414 15 Rubber foot BPB0247 16 Inspection plug seal BPB0502 17 Inspection plug BPB0243...

Страница 14: ...B1102 7 1 4 Male Female Female tee BPB1109 8 Non return valve BPB1086 9 1 4 10 Bar relief valve BPB1084 10 Handle insert BPB0076 11 Drain tap BPB1138 12 250mm drain tube BPB0414 Ref No Description Part no 13 Siphon tube BPB0034 14 Pressure switch BPB1074 15 1 4 Male 1 4 Male adaptor BPB1078 16 On off valve BPB1079 17 Filter regulator BPB1080 18 Regulator gauge BPB1077 19 Vessel pressure gauge BPB1...

Страница 15: ...tee BPB1095 8 300mm Delivery pipe BPB1087 9 Non return valve BPB1086 10 1 4 Male Female Female tee BPB1109 11 1 4 10 Bar relief valve BPB1084 12 Handle insert BPB0076 Ref No Description Part no 13 Drain tap BPB1138 14 250mm Drain tube BPB0414 15 Siphon tube BPB0035 16 Pressure switch BPB1074 17 1 4 Male 1 4 Male adaptor BPB1078 18 On off valve BPB1079 19 Filter regulator BPB1080 20 Regulator gauge...

Страница 16: ...B1004 16 Cylinder block BPB1012 17 Air filter BPB1003 18 Overload clip BPB1001b 19 Overload cover BPB1001b 20 Overload gasket BPB1001b 21 Overload BPB1001a 22 Con rod washers BPB1013a 23 Split pin BPB1015 24 Gudgeon pin BPB0100 25 Con rod washers BPB0102 26 Piston rings 2 BPB1013c 27 Valve plate gasket BPB1014 28 Valve plate BPB1015 29 Cylinder head gasket BPB1016 30 Cylinder head BPB1017 31 Botto...

Страница 17: ...Start relay 110v BPB0138 11 Overload 220 240v BPB1052 11 Overload 110v BPB0139 12 Mounting set 4 BPB1055 13 Sight glass BPB1009 14 Sight glass seal BPB1010 15 Bottom casing BPB1056 16 Outlet elbow BPB0065 17 Delivery pipe gasket BPB1042 18 Delivery bolt BPB1039 19 Delivery pipe BPB1041 20 Sealing ring bolt nut BPB1060 21 Bearing bolt 3 BPB1028 22 Bearing BPB1029 23 Gasket BPB1044 24 Mounting sprin...

Страница 18: ...ON OFF Fig 1 Fig 3 Fig 4 Fig 5 _ 16 Click Fig 2 SB42 46 a ...

Страница 19: ...Fig 6 17 Fig 6 Fig 8 Fig 9 Fig 7 Click SB42 46 ...

Страница 20: ...Issue 1 11 06 ...

Отзывы: