ENGLISH
6 / 32
0006081530_201711
TECHNICAL SPECIFICATIONS
MODEL
TBG 85 ME
TBG 120 ME
TBG 150 ME
TBG 210 ME
TBG 260 ME
Maximum natural gas heat power
kW
850
1200
1500
2100
2600
Minimum natural gas heat power
kW
170
240
300
400
450
¹) natural gas emissions
mg/kWh
Class 2
Class 2
Class 2
Class 2
Class 2
Operation
Two-stage
progressive /
modulating burner
Two-stage
progressive /
modulating burner
Two-stage
progressive /
modulating burner
Two-stage
progressive /
modulating burner
Two-stage
progressive /
modulating burner
50 Hz natural gas transformer
26 kV 40 mA -
230 V
26 kV 40 mA -
230 V
25 kV 40 mA -
230 V
26 kV 40 mA -
230 V
26 kV 40 mA -
230 V
Maximum natural gas heat rate
Stm³/h
90
127
158.7
222
275.1
Minimum natural gas heat rate
Stm³/h
18
25.4
31.8
42.3
47.6
Maximum natural gas pressure
hPa
(mbar)
360
360
360
360
360
Minimum natural gas pressure
hPa
(mbar)
31
20
21.7
24
40
Maximum propane thermal power
kW
850
1200
1500
2100
2600
Minimum propane thermal power
kW
170
240
300
400
450
Maximum propane thermal flow rate
Stm³/h
34.7
49
61.3
85.9
106.38
Minimum propane thermal flow rate
Stm³/h
6.9
9.8
12.3
16.4
18.4
Maximum propane pressure
hPa
(mbar)
360
360
360
360
360
Minimum propane pressure
hPa
(mbar)
31
30
46
36.5
80
²)propane emissions
mg/kWh
Class 2
Class 2
Class 2
Class 2
Class 2
50hz fan motor
kW
1.1
1.5
2.2
3
5.5
60hz fan motor
kW
1.1
1.5
2.6
3.5
5.5
Absorbed electrical power* 50hz
kW
1.6
2
2.8
3.7
6.5
Absorbed electrical power* 60hz
kW
1.6
2
3.2
4.2
6.5
50 Hz power supply voltage
3N~ 400V ± 10% 3N~ 400V ± 10% 3N~ 400V ± 10% 3N~ 400V ± 10% 3N~ 400V ± 10%
Protection rating
IP 40
IP 40
IP 40
IP 40
IP 40
Flame detection
IONISATION
PROBE
IONISATION
PROBE
IONISATION
PROBE
IONISATION
PROBE
IONISATION
PROBE
Control box
BT 320
BT 320
BT 320
BT 320
BT 320
Air flow rate regulation
ELECTRONIC
CAM
ELECTRONIC
CAM
ELECTRONIC
CAM
ELECTRONIC
CAM
ELECTRONIC
CAM
Operating ambient air temperature
°C
-15 ÷ +40
-15 ÷ +40
-15 ÷ +40
-15 ÷ +40
-15 ÷ +40
Sound pressure**
dBA
73
75.5
79
85
87.8
* Total absorption at start-up with ignition transformer on.
Calorific power below reference conditions 15° C, 1013 hPa (mbar):
Natural gas: Hi = 9,45 kWh/Stm³ = 34,02 MJ/Stm³
Minimum gas pressure, depending on the type of gas train used for obtaining max. flow rate with null pressure in the combustion
chamber.
** The acoustic pressure measured with burner operating at maximum rated thermal output refers to the manufacturer's laboratory
environment conditions and cannot be compared to measurements carried out in different locations.
Содержание TBG 85 ME
Страница 2: ......
Страница 31: ...ITALIANO 29 32 0006081530_201711 SCHEMI ELETTRICI...
Страница 32: ...ITALIANO 30 32 0006081530_201711...
Страница 33: ...ITALIANO 31 32 0006081530_201711...
Страница 63: ...ENGLISH 29 32 0006081530_201711 WIRING DIAGRAMS...
Страница 64: ...ENGLISH 30 32 0006081530_201711...
Страница 65: ...ENGLISH 31 32 0006081530_201711...
Страница 67: ......