background image

User’s and technical staff manual 

Dear customer, 

 

Thank you for purchasing our water heater. 
When purchasing the appliance please check: 

 

Scope of delivery and water heater’s resalable condition; 

 

Compatibility of pressure and type of gas (NG or LPG) used by you with the type of gas indicated in 
sections 15 of the following manual and in the table on the appliance’s. 

You should also require from the selling organization to fill in the warranty repair coupons. 
When purchasing an appliance against a credit, the payment schedule should be drawn up with indica-

tion of full due and payable amount. The payment schedule should be signed by the Customer with the date 
indicated and with print full name.  

The present manual contains information about the order of installation of the appliance and rules of its 

exploitation and technical service, following it will provide long-term failure-free and safe operation of the 
appliance.   

Please get carefully acquainted with this manual and follow its instructions. 
 

Best regards 

Armavirsky Plant of Gas Equipment, Ltd.,

 

 

Telephone number of the unified technical support Service 8 800 555 40 35 

(free call on the territory of Russian Federation, working hours of the service: twenty-four-hour) 

 

 

Installation of the appliance, instruction of the owner on the appliance’s operating principles and rules of exploita-
tion, technical service, failure elimination and repair are effectuated only by a specialized service organization.  
Checking and cleaning of the exhaust flue, repair of water communications are performed by residential operational 
services upon request of the appliance’s owner. 
The responsibility for safe exploitation of the appliance and its maintenance in appropriate condition is on its owner. 
Non-compliance with the safety measures and installation rules, rules of use and technical service, can cause fire, 
burn, gas poisoning or poisoning with carbonic oxide (CO). 

 

Armavirsky Plant of Gas Equipment Ltd. Is constantly working on improvement of output products and re-
serves the right for insertion of necessary changes in the water heater’s construction. The following changes 
might not be displayed in the user’s manual. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
30.05.2013 
 
 

Содержание NEVALUX-5611

Страница 1: ...tGaz NEVALUX LUX INSTANTANEOUS GAS WATER HEATER FOR DOMESTIC USE BaltGaz NEVALUX 5611 TU 4858 008 26985921 2008 USER S MANUAL TOGETHER WITH THE INSTRUCTIONS ON MOUNTING TECHNICAL SERVICE AND RE PAIR O...

Страница 2: ...s instructions Best regards Armavirsky Plant of Gas Equipment Ltd Telephone number of the unified technical support Service 8 800 555 40 35 free call on the territory of Russian Federation working hou...

Страница 3: ...allation 7 7 Connecting the appliance to the exhaust flue 7 8 Installation of the appliance s power elements 7 9 Checking the appliance 16 7 10 Rendering the appliance to another type and pressure of...

Страница 4: ...nt of micro switch water flow sensor 13 13 Battery section replacement 13 14 Replacement of the water and gas unit s electromagnetic valve 13 15 Replacement of the electronic control block ANNEX I sch...

Страница 5: ...the appliance until troubleshooting 1 4 At the appliance s normal operation and when the gas pipeline is in good order there should not be any smell of gas in the premise IF YOU FEEL THE SMELL OF GAS...

Страница 6: ...fect kW 18 2 2 3 Performance index at least 84 2 2 4 Gas type NG G20 or LPG G30 2 2 5 Family gas group 2 nd H or 3 rd B P 2 2 6 Rated gas pressure kP mm w g NG G20 2nd family group H LPG G30 3family g...

Страница 7: ...age 1 3208 06 600 Mounting hardware set 1 Spare parts 3103 00 014 Gasket D19 x d10 x 2 2 Note power elements are not included into the delivery set 2 4 Overall and connection dimensions 1 knob of wate...

Страница 8: ...water consumption At that in the knob s position Minimal consumption the appliance s staring up happens at water consumption not less than least 2 5 l min in the position Maximal consumption at water...

Страница 9: ...essary to immediately block gas supply by means of the gas stop valve of the appliance s inlet Then it is necessary to address to the special service organization for appliance s repair 3 4 Replacing...

Страница 10: ...It is forbidden to use a detergent of heightened effect and containing abrasive particles gasoline or any other organic sol vents to clean the surface of the casing and plastic parts ATTENTION It is a...

Страница 11: ...e do not use the appliance the appliance can be used Scheme 7 Way of testing draught in the exhaust flue 7 1 5 The appliance must be installed on the fire resistant walls brick concrete with a ceramic...

Страница 12: ...maintenance it is necessary to install by the appliance s inlet a stop valve on the cold water supply pipeline scheme 9 The stop valve must be easily accessible 7 3 3 Connecting appliance to the water...

Страница 13: ...2 5 m and the inner diameter not less than 12 mm A flexible hose for gas supply should be resistant to the supplied gas at given temperature and pressure Rules of flexible hoses installation are given...

Страница 14: ...40 P see table 1 and scheme 7 Flue pipe s material should be corrosion resistant nonflammable and sustain durable operation at the temperature up to 200 recommended materials stainless steel zinc pla...

Страница 15: ...omatic safety devices operation p 8 4 7 and water heating temperature It is necessary to perform the appliance s switching on and off water temperature regulation in accordance with the section 3 Chec...

Страница 16: ...water flowing through its pipes thermo relay 16 draught sensor is designed to switch the appliance off in case of no draught in the exhaust flue or if its rare faction is less than 1 96 P The thermo r...

Страница 17: ...User s and technical staff manual 1 water consumption regulator 12 heat exchanger 2 gas consumption regulator 13 electromagnetic valve...

Страница 18: ...at provide gas access to the burner only in case if there is water flow stop of gas supply to the burner in case if its flame goes out switching the appliance off in case of no draught in the exhaust...

Страница 19: ...posit on the plug s elec trode Effectuate cleaning of the plug s electrode from soot deposit The electronic control block micro switch or water unit membrane is out of order Replace the devices that a...

Страница 20: ...ter consump tion The burner s flame doesn t go out when the hot water tap is closed Jamming of the rod of the water or gas unit Close the gas stop valve by the appliance s inlet and call a specialized...

Страница 21: ...stic parts ATTENTION It is allowed to perform all operations for the appliance s treatment only after the appliance is switched off and has cooled down 12 3 Technical service During technical service...

Страница 22: ...hermo relay is out of order it must be replaced by removing it from the gas removal device scheme 12 14 Only a thermo relay provided by the company manufacturer can be used for replacement After repla...

Страница 23: ...he gas removal device and remove it 13 3 3 Unscrew two captive nuts from the heat exchanger s fittings 2 and remove it 13 3 4 Install a new heat exchanger 13 3 6 Check the joints subject to disassembl...

Страница 24: ...eration with a new plug or new flame sensor 13 11 Replacement of water temperature sensor 13 11 1 Remove the casing see p 13 1 13 11 2 Disconnect two cables from the temperature display 12 13 11 3 Scr...

Страница 25: ...Manual for technical staff ANNEX I scheme of the appliance with separated components Scheme 18 View of the appliance with separated parts...

Страница 26: ...Manual for technical staff Scheme 19 Components of the water and gas unit 3275 02 200 Scheme 20 Components of the water unit STG W4P1 T...

Страница 27: ...1 3227 02 140 20 Carrier 3272 02 001 21 Plank 3272 02 002 22 Thermo relay 3222 15 000 23 Carrier 3295 07 00 001 24 Cable 3222 14 000 01 25 Loop 3222 00 025 26 Gasket D19xd10x2 3103 00 014 27 Membrane...