7
2013_TETRIS_INSTAL
Look figure 1!
3.5. ELECTRICAL CONNECTION REQUIREMENTS
• Before installation make sure that the electrical wiring system is grounded, complies with the stand-
ards in force and there is no voltage in the lines.
• The bath is permanently connected to the power supply network according to Figure 2. Attention
must be paid to local regulations and allowed load for a phase.
• The bath is constructed according to the requirements of installing class II and is intended for con-
necting as a stationary installation to a commonly used low-voltage electric network 230/400V with
protective earthing circuit, allowed voltage fluctuation -10 up to +5%.
• The bath is designed for use in electrical wiring system with a neutral conductor and a protective
earth conductor (System TN-S).
• This unit must be connected to supply circuits that are protected by a ground fault circuit interrupter
(GFCI) 30 mA and an overload current circuit breaker.
• Connect the feeder to the marked plastic junction box through a free cable gland, it is important to
tighten the glands gasket round the cable, in a way that visually proves the connection to be water-
proof. Also pay attention to fix the cover of the plastic box after connecting the feeder.
• While installing a bath mixer, connect the mixer with earthing bars of the bath’s frame, using wire of
2,5 mm² of cross section.
• For local equipotent bonding it is important to connect all extraneous conductive parts within the
room:
- Metal water-, gas-, drainpipes;
- Metal pipes of central heating/air conditioning;
- Metal constructions of the building;
- Other metal parts nearby that might be a subject to electric potential.
3.6. STARTING UP THE RADIO
• Connect the loudspeakers located in the roof.
• Untangle the antenna located on the backside of the wall of the cabin and place it on the roof or on
the wall.
• After performing the electrical connections of the cabin, switch on the radio and try to find radio sta
-
tions (see User Manual).
• By changing the position and direction of the antenna, try to find an optimum position with the best
audibility and number of received stations.
• When the result is satisfactory, fix the antenna, but not to metal structures.
4. MAINTAINANCE
Xonyx™ solid surface baths and shower trays are finished with a silky surface finish. Xonyx™ is a
very durable product that will last for years with simple care. Follow the recommendations below to
properly clean Xonyx™ solid surface product.
4.1. EVERYDAY CARE
• It is recommended to clean the bathtub/shower cabin immediately after every use with thorough
rinse of warm water and dry with soft and dry cloth to avoid water stains.
• Washing with soap or hand dishwashing liquid and water is usually sufficient to remove surface dirt
or stains.
• Upon need of thorough cleaning wide variety of bath cleaning sprays sold with safety labelling al-
lowing the cleaning of such surface or commercially available solid surface cleaners are effective.
• Drying is an important step, preventing a build-up of soap film or cleaning residue, which can create
the appearance of light scratches over time.
4.2. PREVENTING DAMAGE
Some chemicals are not compatible with Solid Surface materials, and could permanently harm the
surface beyond repair. Avoid surface contact with:
Содержание TETRIS
Страница 1: ...TETRIS Paigaldusjuhend Installation manual...
Страница 2: ...2...
Страница 10: ...10 2013_TETRIS_INSTAL 3 1 5 4 1 2 5 1 5 5 2 II 230 400 10 5 TN S TT IT 30 2 5 5 6...
Страница 11: ...11 2013_TETRIS_INSTAL 6 Xonyx Xo nyx Xonyx 6 1 6 2 Xonyx Xonyx 6 3...
Страница 12: ...12 2013_TETRIS_INSTAL 6 4 6 5 6 6...
Страница 13: ...13 2013_TETRIS_INSTAL...
Страница 15: ...15 2013_TETRIS_INSTAL...
Страница 16: ...16 2013_TETRIS_INSTAL R R Q Q A R Q Q A C R C...
Страница 17: ...17 2013_TETRIS_INSTAL INSIDE EasyClean INSIDE EasyClean INSIDE EasyClean...
Страница 18: ...18 2013_TETRIS_INSTAL R C...
Страница 19: ...19 2013_TETRIS_INSTAL R C R C R C...
Страница 20: ...20 2013_TETRIS_INSTAL...
Страница 21: ...21 2013_TETRIS_INSTAL R D...