Baltech TL-0208C Скачать руководство пользователя страница 11

To select an operation mode and set up parameters of the 
device,  use  the  button  «MODE».  The  selection  of  the 
required mode is performed by multiple pressing of a button 
and  through  control  of  the  required  mode  on  the  device 
display. The device operation modes and sequence of their 
selection  are  shown  on  the  figure  3.4.  After  the  mode  is 
selected,  press  the  measurement  start  button  and  start 
measuring. Release the button to switch off the device. The 
device will switch off in about 6 seconds. 

3.3.2 Operation modes of the device

Operation mode 

Parameter Setup 

Figure 3.4

1.

 Scanning and displaying 

temperature during 
measurement 

2. 

Maximum temperature 

during measurement 

3. 

Minimum temperature 

during measurement 

4.

 Average  temperature 

during measurement 

5.

 The difference between 

the maximum and the 
minimum temperature 
during measurement 

6. Recalling the stored 
measurement results by 
using 

 or

 

 buttons. 

7. Setting of a controlled 
surface emissivity 
8. Setting of the highest 
alarm temperature
9. Setting of the lowest 
alarm temperature

(The parameters are set 
with 

 or 

 buttons) 

Содержание TL-0208C

Страница 1: ...www baltech biz OPERATION MANUAL infrared thermometer...

Страница 2: ...s 3 2 1 Safety measures 3 2 2 External examination 3 2 3 Preparation 3 2 4 Selection of measurement units and laser pointer 3 2 5 Battery changing 3 3 Work with the device 3 3 1 LCD display and contro...

Страница 3: ...nt of surfaces that can t be measured with traditional contact thermometers e g moving or hard to get to objects surfaces of pressurized objects Before you start using the device read this operation m...

Страница 4: ...display Dimensions mm Weight g 0 5 0 5 0 5 1 0 1 0 1 0 50 1 50 1 50 1 0 1 1 0 0 1 1 0 0 1 1 0 9 9 9 Max Min Avr T Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 10 points Yes 10 points 200 127 47...

Страница 5: ...tted energies figure 2 1 are collected and focused on the infrared detector A built in digital processor converts the information into temperature data in accordance with the selected operation mode a...

Страница 6: ...arked with a nameplate on the side face of the measurement unit The nameplate contains the device name measurement range field of view and manufacturer name The device is packed in a plastic carrying...

Страница 7: ...an lead to inaccurate measurement results due to the creation of obstacles for the device s optics When operating with the laser pointer do not direct the laser beam towards eyes or mirror surfaces fi...

Страница 8: ...experimentally paragraph 3 3 4 of this operation manual If necessary one can perform modification of a controlled surface for the purpose of emissivity increasing It is also necessary to make sure tha...

Страница 9: ...DEVICE APPLICATION LASER ON OFF C F Figure 3 2...

Страница 10: ...isplay and control buttons are shown on the figure 3 3 3 3 Work with the device 3 3 1 LCD display and control panel Laser pointer on off Battery Low Data storage T Emissivity Alarm t min or t max Memo...

Страница 11: ...the device The device will switch off in about 6 seconds 3 3 2 Operation modes of the device Operation mode Parameter Setup Figure 3 4 1 Scanning and displaying temperature during measurement 2 Maximu...

Страница 12: ...g to press the start measurement button The device will operate continuously in the selected mode without automatic shutdown 3 In scan mode the LCD displays both the current temperature in Celsius or...

Страница 13: ...he measurement spot diameter The FOV diagram is shown on the figure 3 5 3 3 3 Field of View FOV The field of view for this device is determined at the distance of 1 meter from the lens At smaller dist...

Страница 14: ...ark scotch tape friction tape on the measured surface or coat it with black mat paint Carry out measurement of the modified surface when this material has the same temperature as the controlled object...

Страница 15: ...e Copper Dirt Frozen food Hot food Glass plate Ice Lead Limestone Oil Paint Paper Plastic Rubber Sand Leather Snow Steel Textiles Wood Water 0 30 0 95 0 95 0 70 0 50 0 90 0 85 0 95 0 95 0 95 0 94 0 90...

Страница 16: ...ned with compressed air jet or soft brush It is recommended to clean the device housing using soft jaw or cloth moistened with soap solution The device must be transported and stored in the carrying c...

Страница 17: ...ssue date ___ __________201_ Signature ______________ Job position and signature of the manufacturer s representative The infrared thermometer BALTECH TL ____ _____ is manufactured according to the sp...

Страница 18: ...CALIBRATION CERTIFICATE...

Страница 19: ...he warranty period begins from the date the warranty certificate was filled in but not later than 1 month after the delivery of the equipment The warranty is not valid if the customer registration for...

Страница 20: ...BALTECH GmbH www baltech biz Kronsforder Allee 45 23560 L beck Germany Tel 49 0 451 370 87 700 E Mail info baltech biz...

Отзывы: