background image

- 10 -

Suggested Wiring Options for Dual Output Alternators

Содержание Max Charge MC-612

Страница 1: ...ome entangled in your motor or other machinery 3 Wear ANSI approved safety glasses 4 DO NOT attempt to modify the regulator Alterations could result in damage to your charging system and will void you...

Страница 2: ...ulator see illustration The sec ond BLACK ground wire in the harness attaches to the Negative Battery Sense Terminal Both BLACK wires attach to preferred ground terminal on the alternator A user suppl...

Страница 3: ...perature compensation and activating warning alarm Battery 2 terminal activates the warning alarm only The upper volt age limit for battery compensation is 14 8 volts If higher voltage limits are desi...

Страница 4: ...aled Gel Cell GEL For sealed gel batteries Absorbed Glass Mat AGL For AGM batteries Optima OPS For Optima spiral wound batteries Flooded Standard FSB For standard lead acid batteries Halogen HAL For v...

Страница 5: ...s LD Mode 11 Factory use only LD Mode 12 Factory use only LD Mode 13 Run time Hr code is followed by a numeric readout in 1 10 hr increments LD Mode 14 Tach reading Activate and adjust for alternator...

Страница 6: ...12 2 1 ACTIVATE RELEASE PrA display cycles to ALC followed by OFF code 2 ACTIVATE HOLD OFF display cycles to numeric calibration values When the proper calibration value is reached RELEASE Compensatio...

Страница 7: ...tor brushes and rotor are likely to be working properly If the system is not charging remove the alternator and have it inspected by a qualified alternator shop T Te es st t B B If there is little or...

Страница 8: ...ine if your alternator may be the source of charging difficulties If the pre ceding tests do not prove the existence of a failure within the regulator or alternator we recommend you contact a licensed...

Страница 9: ...9 Suggested Wiring Options for Single Output Alternators...

Страница 10: ...10 Suggested Wiring Options for Dual Output Alternators...

Страница 11: ...arged This occurs as a result of the regulator s effort to provide a blip of volt age to the alternator to keep the tachometer feed activated This voltage creep can usually be reduced or eliminated by...

Страница 12: ...gnition switch or an independent ungrounded oil pressure switch are both acceptable connection points A toggle switch may be added to this circuit to shut down the alternator load in cases where maxim...

Отзывы: