37
BVS Cockpit
Slot
Module
Function
0
Header module of
SMARTCAMERA
Parameter configuration, no process data
1
SMARTCAMERA
Process data
2
IO-Link port
IO-Link data modules of various data widths or configurable as
a standard I/O port; IO-Link parameterization
3
IO-Link station diagnostics or IO-Link
extended diagnostics
Slots for optional IO-Link additional modules
4
Input pin 4
5
Output pin 4
6
Restart pin 4
7
Input pin 2
8
Output pin 2
9
Restart pin 2
5.7.3
Coding IO-Link data modules (slot 2)
Data modules for standard I/O ports
Data module
Data width
Standard I/O
0 byte; (see “Additional modules (slot 3 to 9)”)
5.7.4
Data modules for IO-Link inputs
Data module
Data width
IOL_I_1byte
1 byte
IOL_I_2byte
2 bytes
IOL_I_4byte
4 bytes
IOL_I_6byte
6 bytes
IOL_I_8byte
8 bytes
IOL_I_10byte
10 bytes
IOL_I_16byte
16 bytes
IOL_I_24byte
24 bytes
IOL_I_32byte
32 bytes
Data modules for IO-Link outputs
Data module
Data width
IOL_O_1byte
1 byte
IOL_O_2byte
2 bytes
IOL_O_4byte
4 bytes
IOL_O_6byte
6 bytes
IOL_O_8byte
8 bytes
IOL_O_10byte
10 bytes
IOL_O_16byte
16 bytes
IOL_O_24byte
24 bytes
IOL_O_32byte
32 bytes
Содержание SMARTCAMERA BVS SC 1280Z00-30 Series
Страница 1: ...BVS SC _1280Z00 30 0 0 SMARTCAMERA Fieldbus...
Страница 2: ......
Страница 5: ...www balluff com 5 BVS Cockpit User s manual...
Страница 43: ...www balluff com 43 BVS Cockpit Determining the station name 1 Define the PROFINET station name of the device...
Страница 53: ...www balluff com 53 BVS Cockpit 3 Select SMARTCAMERA Module BVS_SC 1280 and apply to the configuration...