1-800-543-8390
•
WWW.BALLUFF.COM
10
BTL5-A/C/E/G__-M____-B/Z-S32/KA__
Micropulse Linear Position Transducer
Analog Output-Rod Style
™
If an existing configuration needs
to be deleted, all values can be
restored to the original factory
settings (Reset).
Activate buttons:
1. Press one of the buttons for at
least 3 s. Release button.
2. Within 1 s hold down buttons
1+2 simultaneously for at least
3 s. Now the Error value
remains stored as the output
signal.
If an error occurs or there is
an interruption while activating
a button, please wait for an
additional 12 s before starting
over.
Perform reset:
3. Hold down both buttons for at
least 6 s. The Null value is
displayed, and the reset has
taken place.
4. Release buttons. The current
position value is displayed and
the buttons are again deacti-
vated.
The transducer is ready for new
calibration.
9 Resetting all values (Reset)
10.50
V
V
V
0.00
8.43
5.39
5.39
V
V
V
>6 s
3.60
m
A
m
A
15.67
10.80
10.80
m
A
m
A
m
A
m
A
4.00
1
/ 2
1
+ 2
1
+ 2
10.50
3.60
>3 s
<1 s
>3 s
Displayed values (example)
at 0...10 V at 4...20 mA
Code =
Error value
Code =
Error value
Current
position value
Current
position value
Code =
Null value
Current
position value
(factory setting)
Enable buttons
Reset
Z_Analog_122003.pmd
12/11/2003, 3:47 PM
10