www.balluff.com
13
english
6
IO-Link interface (continued)
6.5
System parameters
Index
Parameters
Subindex
Parameters
Data format
Access
Comments
Hex
Dec
Hex Dec
000D 13
Profile characteristic 01
1
DeviceProfileID
UINT16
Read only
Smart Sensor Profile
02
2
FunctionClassID
Process value
03
3
FunctionClassID
Process data
variable
000E 14
PDInput descriptor
01
1
PDV1
OctetStringT 3
Read only OutOfRange
02
2
PDV2
Position value
Tab. 6-5: System parameters
6.6
Sensor-specific parameters
Index
Parameters
Subindex Data format
(length)
Access
Value
range
Comments
Hex
Dec
Hex Dec
0052 82
Temperature array
00
0
Char (5 bytes)
Read only –128…+127 Output of all
temperature
parameters (in °C)
Internal temperature
01
1
Char (1 byte)
Min. temperature startup
02
2
Char (1 byte)
Max. temperature startup 03
3
Char (1 byte)
Min. temperature lifetime
04
4
Char (1 byte)
Max. temperature lifetime 05
5
Char (1 byte)
0055 85
Application specific
number
0
0
Char (1 byte)
Read/
Write
0…255
–
0056 86
COMx speed
00
0
Char (1 byte)
Read only 2
IO-Link COM speed
0057 87
Operating hours array
00
0
12 bytes
Read only
Sensor operating hours
Total hours
01
1
UInt32 (4 bytes)
Read only
Lifetime operating hours
Maintenance hours
02
2
UInt32 (4 bytes)
Read only
Operating hours since
last maintenance
Startup hours
03
3
UInt32 (4 bytes)
Read only
Operating hours since
last startup
0058 88
Startup array
00
0
8 bytes
Read only
Sensor startup numbers
Total startups
01
1
UInt32 (4 bytes)
Read only
Lifetime number of
startups
Maintenance startups
02
2
UInt32 (4 bytes)
Read only
Number of startups
since last maintenance
00C0 192 Gradient
00
0
Float32
1)
(4 bytes) Read only
Gradient of curve
(Output
→
Position)
00C1 193 Offset
00
0
Float32
1)
(4 bytes) Read only
Curve offset
(Output
→
Position)
00C5 197 Inversion
00
0
UChar (1 byte)
Read/Write 0x00-0x01
Curve inversion
00C8 200 Slmin[mm]
01
1
Float32
1)
(4 bytes) Read only 0…133
Current value for
Slmin[mm]
Slmax[mm]
02
2
Float32
1)
(4 bytes) Read only 0…133
Current value for
Slmax[mm]
00CA 202 Teach-in Status
0
0
RecordT
Read only
Current status for linear
Teach-in
1)
Please note that floating point values have Little-Endian coding and start with the LSB.
Tab. 6-6: Sensor-specific parameters
BIP LD2-T_ _ _-03-S75
Inductive Positioning System
Содержание LD2-T048-03-S75
Страница 2: ...www balluff com ...
Страница 3: ...Betriebsanleitung BIP LD2 T_ _ _ 03 S75 deutsch ...
Страница 4: ...www balluff com ...
Страница 23: ...User s Guide BIP LD2 T_ _ _ 03 S75 english ...
Страница 24: ...www balluff com ...
Страница 43: ...Notice d utilisation BIP LD2 T_ _ _ 03 S75 français ...
Страница 44: ...www balluff com ...
Страница 63: ...Manuale d uso BIP LD2 T_ _ _ 03 S75 italiano ...
Страница 64: ...www balluff com ...
Страница 83: ...Manual de instrucciones BIP LD2 T_ _ _ 03 S75 español ...
Страница 84: ...www balluff com ...
Страница 103: ...操作手册 BIP LD2 T_ _ _ 03 S75 中文 ...
Страница 104: ...www balluff com ...
Страница 123: ...取扱説明書 BIP LD2 T_ _ _ 03 S75 日本語 ...
Страница 124: ...www balluff com ...
Страница 143: ......