Statistics Data Configuration: Time Period Unit
The time unit
Time Period Unit
can be set with one of the
values from Tab. 5-22 to calculate the minimum, maximum
and average. For example, to calculate minimum,
maximum and average for all 1-hour values, hours can be
selected as the unit for this subindex.
Value
Meaning
Description
0x01 (1)
Seconds
Seconds
0x02 (2)
Minutes
Minutes
0x03 (3)
Hours
Hours
0x04 (4)
Days
Days
0x05 (5)
Samples
Measurement
values
Tab. 5-22: Statistics Data Configuration – Time Period Unit
Statistics Data Configuration: Time Period Value
Time Period Value
can be set from 1 second to 1 week or
1 to 1000 measurement values. Over what average
minimum, maximum and average is the calculation to be
performed. Other checks are performed internally and, if
an unsuitable selection is made for
Time Period Value
, a
standard error is returned.
Time Period Unit
Time Period Value (value
range)
Seconds
1…1000
Minutes
1…100
Hours
1…24
Days
1…7
Measurement values
1…1000
Tab. 5-23: Statistics Data Configuration – Time Period Value
Statistics Data Configuration: Moving Average
Window Unit
For the moving average (
moving average window
), one of
the units from Tab. 5-24 should be selected. For example,
to calculate the moving average for groups of 100
measurement values, measurement values (samples) can
be selected as the unit.
Value
Meaning
Description
0x01 (1)
Seconds
Seconds
0x02 (2)
Minutes
Minutes
0x03 (3)
Hours
Hours
0x04 (4)
Samples
Measurement
values
Tab. 5-24: Statistics Data Configuration – Moving average window
unit
5
Secondary Device Functions (continued)
Statistics Data Configuration: Moving Average
Window Value
The value for the moving average (
moving average
window
) must be in the value range (see Tab. 5-25). To
calculate the moving average, it is possible to select, for
example, 1…1000 measurement values.
Moving Average Window
Unit
Moving Average Window
Value (value range)
Seconds
1…1000
Minutes
1…100
Hours
1…24
Measurement values
1…1000
Tab. 5-25: Statistics Data Configuration – Moving average window
value
Statistics Data Output: Minimum
Minimum value of the measured values over a certain time
period.
Statistics Data Output: Maximum
Maximum value of the measured values over a certain time
period.
Statistics Data Output: Average
Average of the measured values over a certain time period.
Statistics Data Output: Moving Average
The moving average is an average that is calculated
repeatedly over a certain value of the moving average
window.
Statistics Data Configuration: Number of Samples
Total number of read measurement values during start and
stop operation of the minimum value/maximum value/
average function.
BES M12EH1-L01C40B-S04G-L04 / BES M18EH1-L01C80B-S04G-L04
Inductive sensors
Содержание IO-Link BES M12EH1-L01C40B-S04G-L04
Страница 2: ...www balluff com...
Страница 3: ...BES M12EH1 L01C40B S04G L04 BES M18EH1 L01C80B S04G L04 IO Link Konfiguration deutsch...
Страница 4: ...www balluff com...
Страница 95: ...BES M12EH1 L01C40B S04G L04 BES M18EH1 L01C80B S04G L04 IO Link Configuration english...
Страница 96: ...www balluff com...
Страница 187: ......