5
Startup
BVS SC-_1280Z00-07-000
SMART
CAMERA
IO
English
30
All logical signals are permanently linked with the physical signals of the plug connectors. I/O 0
and I/O 1 exists twice.
Signal
I/O 0
I/O 1
I/O 2
I/O 3
I/O 4
I/O 5
I/O 6
I/O 7
Power
Pin 2
Pin 4
I/O
Pin 1
Pin 3
Pin 4
Pin 5
Pin 6
Pin 8
I/O Light
Pin 2
Pin 4
1
2
3
4
1
2
3
4
1
2
3
4
5
6
7
8
+V
DC
I/O 0
GND
I/O 1
+V
ext
I/O 6 Trigger
GND
I/O 7 Boost
+
−
+
−
I/O 0
Common Out
I/O 1
I/O 2
I/O 3
I/O 4
Common IN
I/O 5
24 V
24 V
Power
I/O Light
I/O-Port
I/O 0
I/O 1
I/O 2
I/O 3
I/O 4
I/O 5
I/O 6
I/O 7
Isolation
Figure 24: Control plan
If I/O 0 is operated as output, pin 1 at the I/O connection and pin 2 at the power connection are
switched.
If the I/Os are configured as input, their signals are logically combined with OR. This means, a 1
signal is recognized if a 1 signal is present either at pin 2 of the power connection or pin 1 of the
I/O connection. The same applies to I/O 1.