244
BVS HS-Q Series
Standard Hand Held Barcode Reader
5
References
5.5.2 Stand Mode Off
Time
This feature specifies the amount of time reader illumination stays off after pulling the trigger when
in Stand Mode. The configurable range is 01 to 32 by 01 in increments of 500ms (500ms to 16
seconds).
Follow these instructions to set this feature:
1
Determine the desired setting.
2
Pad the result with leading zeroes to yield two digits. For example: 2 = 02, 5 = 05, 20 = 20,
etc.
3
and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Pro-
gramming Mode.
4
Scan the barcode: Set Stand Mode Illuminator Off Time.
5
Scan the appropriate two digits from the keypad in
Appendix 18, Use the barcodes in this
appendix to enter numbers as you would select digits/characters from a keypad.
, that repre-
sent the setting which was determined in the steps above. You will hear a two-beep indication
after the last character.
6
Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure. See
for some examples of how to set
this feature.
Stand Mode Off
Time
STEP ACTION
EXAMPLES
1
Desired Setting
500 ms
1 Second
5.5 Seconds
16 Seconds
2
Pad leading zero
01
02
11
32
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT STAND MODE OFF TIME
5
Scan Two Characters
From
the barcodes in this
appendix to enter
numbers as you would
select digits/characters
from a keypad.
‘0’ and ‘1’
‘0’ and ‘2’
‘1’ and ‘1’
‘3’ and ‘2’
6
Scan ENTER/EXIT PROGRAMMING MODE
Содержание BVS HS-QB-SDR-MA-02-02
Страница 1: ...Balluff BVS HS Q Family Standard Handheld Barcode Reader Operation Manual english...
Страница 282: ...282 BVS HS Q Series Standard Hand Held Barcode Reader 9 Appendix D Keypad A B C D E F...
Страница 295: ...295 www balluff com BVS HS Q Series Standard Hand Held Barcode Reader NOTES...