14
english
6.1
Accuracy
The specifications are typical values for the BTL7-V50E...
at 24 V DC and room temperature, with a nominal length
of 500 mm in conjunction with the BTL-P-1013-4R,
BTL-P-1013-4S, BTL-P-1012-4R or BTL-P-1014-2R
magnet.
The BTL is fully operational immediately, with full accuracy
after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Position resolution
1 µm
Non-linearity with a constant distance
between the magnet and profile:
Nominal length
≤
5500 mm
Nominal length
>
5500 mm
±30 µm
±0.02 % FS
Hysteresis
≤
±10 µm
Repeat accuracy
≤
±5 µm
(typ. ±2.5 µm)
Temperature coefficient
1)
≤
18 ppm/K
Velocity resolution
0.1 mm/s
Min. detectable velocity
1 mm/s
Max. detectable velocity
10 m/s
6.2
Ambient conditions
2)
Operating temperature
−
40°C to +85°C
Storage temperature
−
40°C to +100°C
Humidity
< 90%,
non-condensing
Rod pressure rating (when installed in
hydraulic cylinders)
For Ø 8 mm
< 250 bar
For Ø 10.2 mm
< 600 bar
Shock rating
per EN 60068-2-27
3)
150 g/6 ms
Continuous shock
per EN 60068-2-29
3)
150 g/2 ms
Vibration
per EN 60068-2-6
3)
20 g,
10 to 2000 Hz
Degree of protection per IEC 60529
Connector C003 (when attached)
IP 67
6.3
Supply voltage (external)
Voltage, stabilized
4)
10 to 30 V DC
Ripple
≤
0.5 V
SS
Current draw (at 24 V DC)
≤
120 mA up to 1524 mm
≤
160 mA from 1525 mm
Inrush current
≤
500 mA/10 ms
Reverse polarity protection
Up to 36 V
Overvoltage protection
Up to 36 V
Dielectric strength
(GND to housing)
500 V AC
6.4
Output
Short-circuit resistance
Signal cable to GND
6.5
Dimensions, weights
Rod diameter
8 mm or 10.2 mm
Nominal length
For Ø 8 mm
25 to 1016 mm
For Ø 10.2 mm
25 to 7620 mm
Weight (depends on length)
Approx. 2 kg/m
Housing material
Anodized aluminum
Rod material
Stainless steel 1.4571
Rod wall thickness
For Ø 8 mm
0.9 mm
For Ø 10.2 mm
2 mm
Young's modulus
Approx. 200 kN/mm
2
Housing mounting via threads M18×1.5 or 3/4"-16UNF
Tightening torque
Max. 100 Nm
6.6
Maximum sampling rate f
max
At nominal length
0050 to 0250 mm
0251 to 0600 mm
0251 to 0600 mm
1301 to 2700 mm
2701 to 5500 mm
5501 to 7600 mm
> 7601 mm
1100 Hz
960 Hz
775 Hz
495 Hz
245 Hz
180 Hz
170 Hz
1)
Nominal length = 500 mm, magnet in the middle of the measuring range
2)
For
: Use in enclosed spaces and up to a height of 2000 m above sea
level.
3)
Individual specifications as per Balluff factory standard
4)
For
: The transducer must be externally connected via a limited-
energy circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1, or a class 2 power supply as defined in UL 1310 or
UL 1585.
6
Technical data
BTL7-V50E-M _ _ _ _ -A/B/Y/Z(8)-C003
Micropulse Transducer - Rod Style
Содержание BTL7-V50E-M P-C003 Series
Страница 1: ...BTL7 V50E M_ _ _ _ A B Y Z 8 C003 Betriebsanleitung deutsch...
Страница 2: ...www balluff com...
Страница 21: ...BTL7 V50E M_ _ _ _ A B Y Z 8 C003 User s Guide english...
Страница 22: ...www balluff com...
Страница 41: ...BTL7 V50E M_ _ _ _ A B Y Z 8 C003 Manual de instrucciones espa ol...
Страница 42: ...www balluff com...
Страница 61: ...BTL7 V50E M_ _ _ _ A B Y Z 8 C003 Notice d utilisation fran ais...
Страница 62: ...www balluff com...
Страница 81: ...BTL7 V50E M_ _ _ _ A B Y Z 8 C003 Manuale d uso italiano...
Страница 82: ...www balluff com...