Parameters Subindex Entry
Format
Access Default value
Comment
918
PROFIBUS slave address Unsigned16
125
See sections
922
Telegram selection
Unsigned16 (6)
ro
16#0051 = 81
81: Standard telegram
59001: 1 position value
59002: 2 position values
…
59016: 16 position
values
59033: FMM position
values
59017: 1 position and
speed value
59018: 2 position and
speed values
…
59032: 16 position and
speed values
59034: FMM position
and speed values
964
Drive ID
Array[5] of
Unsigned16
ro
0
Manufacturer ID
Unsigned16 (6)
16#0378 = 888
1
Drive unit type
Unsigned16 (6)
16#DB01 =
56065
2
Firmware version
Unsigned16 (6)
3
Firmware date, year (dec) Unsigned16 (6)
4
Firmware date (decimal):
day x 100 + month
Unsigned16 (6)
965
Profile identification
OctetString[2]
(10)
ro
Byte 1: PROFIdrive
16#3D = 61
PROFIdrive
Byte 2: Version
16#1F = 31
Version (31 only in
compatibility mode)
16#29 = 41
otherwise 41
970
Load preset values of the
local parameters
Unsigned16
rw
0
Value = 0: preset
Value = 1: Load
complete default settings
(After the default state is
loaded successfully, the
value switches back to 0)
971
Write local parameters to
non-volatile memory.
Unsigned16
rw
0
Preset value: 0
value = 1: Start saving.
Saving continues until
the value returns to 0
itself.
972
Reset
Unsigned16
rw
Writing a 1 in this
parameter performs an
immediate reset. See
section 4.11.3
6
Appendix
BTL7-T500-…
Configuration Guide