background image

www.balluff.com

17

english

10.1 

Accuracy

The specifications are typical values for BTL6-A/C/E/G... at 
24 V DC and room temperature, with a nominal length of 
500 mm in conjunction with the BTL5-P-3800-2, 
BTL5-P-4500-1, BTL5-P-5500-2, BTL6-A-3800-2, 
BTL6-A-3801-2, BTL5-F-2814-1S or BTL5-T-2814-1S 
magnet.
The transducer is fully operational immediately, with full 
accuracy after warm-up.

For special versions, other technical data may 
apply.
Special versions are indicated by the suffix -SA 
on the part label.

Resolution

BTL6-A/G...

350 µV
≥ 5 µm

BTL6-C/E...

700 nA
≥ 5 µm

Repeat accuracy

≤ ±0.002 % FS
≥ ±5 µm

Sampling rate  
(dependent on the nominal length)

Max. 2 kHz

Non-linearity at  
  Nominal length ≤ 500 mm
  Nominal length > 500 mm

±200 µm
±0.04 % FS

Temperature coefficient

1)

 

≤ 30 ppm/K

Max. detectable speed

10 m/s

10.2 

Ambient conditions

2)

 

Operating temperature

−25°C…+70°C

Storage temperature

−40°C…+100°C

Relative humidity

< 90%, non-condensing

Shock rating 
Continuous shock  
per EN 60068-2-27

3)

50 g/6 ms 
50 g/2 ms

Vibration  
per EN 60068-2-6

3)

 

12 g, 10…2000 Hz

Degree of protection per 
IEC 60529

IP67

(when attached)

10.3 

Supply voltage (external)

Voltage, stabilized

4)

10…30 V DC

Ripple

≤ 0.5 V

PP

Current draw (at 24 V DC)

≤ 150 mA

Inrush current

≤ 3 A/0.5 ms

Reverse polarity protection

5)

Up to 36 V

Overvoltage protection

Up to 36 V

Dielectric strength  
(GND to housing)

500 V DC

10.4 

Output

BTL6-A… Output voltage
 

    Load  current

0…10 V
Max. 5 mA

BTL6-C… Output current
 

     Load  resistance

0.1…20 mA
≤ 500 ohms

BTL6-E… Output current
 

    Load  resistance

4…20 mA
≤ 500 ohms

BTL6-G… Output voltage
 

     Load  current

−10…10 V
Max. 5 mA

Short circuit resistance

Signal cable to 36 V
Signal cable to GND

10.5 

Input

Programming inputs La/Lb

10…30 V DC
High-active

Overvoltage protection

Up to 36 V

10.6 

Dimensions, weights

Housing height

20.8 mm

Nominal length

50…4572 mm

Weight (depends on length)

Approx. 1 kg/m

Housing material

Aluminum

1)

 Nominal length 500 mm, magnet in the middle of the measuring range

2)

 For 

: Use in enclosed spaces and up to a height of 2000 m above sea 

level.

3)

 Individual specifications as per Balluff factory standard, resonances 

excluded

4)

 For 

: The transducer must be externally connected via a limited-

energy circuit as defined in UL 61010-1, a low-power source  

as defined in UL 60950-1, or a class 2 power supply as defined  

in UL 1310 or UL 1585.

5)

 A prerequisite is that no current can flow between GND and 0 V in the 

event of polarity reversal.

10 

Technical data

BTL6-A/C/E/G500-M _ _ _ _ -PF-S115
Micropulse Transducer in a Flat Profile Housing

Содержание BTL6-A/C/E/G500-M Series

Страница 1: ...BTL6 A C E G500 M _ _ _ _ PF S115 User s Guide english...

Страница 2: ...www balluff com...

Страница 3: ...display 7 4 Installation and connection 8 4 1 Installing the transducer 8 4 2 Captive magnets 8 4 3 Floating magnets 9 4 4 Electrical connection 10 4 5 Shielding and cable routing 10 5 Startup 11 5 1...

Страница 4: ...in a Flat Profile Housing 11 Accessories 18 11 1 Captive magnets 18 11 2 BTL2 GS10 _ _ _ _ A joint rod 18 11 3 Floating magnets 18 11 4 Connector 19 11 5 Adjusting box 19 12 Type code breakdown 20 13...

Страница 5: ...e magnets are available in various models and must be ordered separately 1 4 Approvals and markings UL approval File no E227256 US Patent 5 923 164 The US patent was awarded in connection with this pr...

Страница 6: ...ertaining to the work to be done The operator is responsible for ensuring that local safety regulations are observed In particular the operator must take steps to ensure that a defect in the position...

Страница 7: ...s at ultrasonic speed Fig 3 1 BTL6 transducer construction The component of the torsional wave which arrives at the end of the waveguide is absorbed in the damping zone to prevent reflection The compo...

Страница 8: ...he transducer is electrically isolated from the machine with the supplied insulating bushes see Figure 3 1 1 Guide the transducer into the mounting clamps 2 Attach transducer to the base using mountin...

Страница 9: ...L5 P 5500 2 5 15 mm 15 mm BTL5 P 4500 1 0 1 2 mm 2 mm BTL6 A 3800 2 4 8 mm2 5 mm BTL6 A 3801 2 4 8 mm2 5 mm 1 The selected distance must stay constant over the entire measuring length 2 For optimum me...

Страница 10: ...Shield is internally connected to connector housing Magnetic fields The position measuring system is a magnetostrictive system It is important to maintain adequate distance between the transducer and...

Страница 11: ...or system manufacturer 1 Check connections for tightness and correct polarity Replace damaged connections 2 Turn on the system 3 Check measured values and adjustable parameters and readjust the trans...

Страница 12: ...procedure notes Prerequisites Programming inputs are connected The transducer is connected to the system controller Voltage or current values from the transducer can be read using a multimeter the sys...

Страница 13: ...point Move magnet to the new end position Read new end point by activating the programming inputs The current null point remains the same New end point Before After Fig 6 3 Reading new end point 6 Cal...

Страница 14: ...null point 1 04 V 4 82 mA Activate a for at least 2 s 2 s a The new null point is set after activation 0 00 V 4 00 mA 3 Set end point Bring magnet to the new end point 9 89 V 19 13 mA Activate b for a...

Страница 15: ...4 s 4 s b 5 39 V 9 15 mA 2 Invert gradient Activate a and b simultaneously for at least 4 s 4 s a b After activation 5 61 V 14 85 mA The output gradient is inverted Current position value is displaye...

Страница 16: ...LED 1 Activate reset Simultaneously activate a and b for at least 4 s 4 s a b 2 Reset Simultaneously activate a and b for at least 4 s 4 s a b After activation All values are reset Current position v...

Страница 17: ...P Current draw at 24 V DC 150 mA Inrush current 3 A 0 5 ms Reverse polarity protection5 Up to 36 V Overvoltage protection Up to 36 V Dielectric strength GND to housing 500 V DC 10 4 Output BTL6 A Outp...

Страница 18: ...joint rod Weight Approx 150 g m Material Aluminum 1 State the nominal length when ordering Example BTL2 GS10 0100 A nominal length 100 mm 11 3 Floating magnets BTL5 P 3800 2 38 28 9 14 4 2 Fig 11 4 I...

Страница 19: ...mation on pin assignment see Table 4 2 on page 10 BKS S115 PU _ _ Straight connector molded on cable preassembled M12 8 pin Various cable lengths can be ordered e g BKS S115 PU 05 Cable length 5 m Fig...

Страница 20: ...nterface current output 0 1 20 mA E Analog interface current output 4 20 mA Supply voltage 5 10 30 V DC Output gradient 00 Rising factory setting Nominal stroke 4 digit M0500 Metric specification in m...

Страница 21: ...0 35433071 10 0 393700787 Tab 13 1 Conversion table mm to inches 1 inch 25 4 mm inches mm 1 25 4 2 50 8 3 76 2 4 101 6 5 127 6 152 4 7 177 8 8 203 2 9 228 6 10 254 Tab 13 2 Conversion table inches to...

Страница 22: ...any Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Phone 49 7158 173 370 Fax 49 7158 173 691 service balluff de US Service Center USA Balluff Inc 8125 Holton Drive Florence KY 41042 Phone 859 7...

Отзывы: