BTL5-A11-M/U_ _ _ _-P-SA167-S 32
Micropulse Linear Transducer in Profile Housing
5
english
3
Installation (cont.)
3.3
Captive magnets
Lateral forces are to be avoided
when using captive magnets
(
➥
➥
➥
➥
➥
Figs. 3-6 and 3-7). Connections
are required here which permit the
corresponding degree of freedom
with respect to the direction of
movement of the magnet along the
stroke range. It is assumed that the
BTL5-F-2814-1S magnet is con-
nected to the machine member
using a connecting rod. The
BTL2-GS10...A connecting rod
(
➥
➥
➥
➥
➥
Fig. 3-8) is available as an ac-
cessory (please indicate length LG
when ordering).
Fig. 3-5: Dimensional drawing (BTL5...P-KA transducer with captive magnet BTL5-F-2814-1S)
Mounting brackets with isolation bushings
and M5 x 22 cylinder head screws, DIN 912,
max. tightening torque 2 Nm
Nominal stroke
Black,
round
marking
Magnet
NL
Fig. 3-8: BTL2-GS10-_ _ _ _-A
connecting rod
Jam nut DIN 934 M5
Swivel eye DIN 648
Ball joint "B" DIN 71805, rotates hori-
zontally (part of BTL5-F-2814-1S)
Ball joint "B"
DIN 71805,
rotates horizontally
Black, round
marking
Fig. 3-6: BTL5-F-2814-1S magnet
Fig. 3-7: BTL5-M/N-2814-1S magnet
Mechanically joined to M5
stud using 2 nuts
Max. angle offset
Max. parallel offset
BTL5-M-2814-1S:
X = 48.5
Y = 57
BTL5-N-2814-1S:
X = 51
Y = 59.5
Fig. 3-9: Mounting angle (optional)
Insula-
tion
Set-
screw
DIN 916
M6 x 10
Screw ISO 4762 M6 x 20
max. torque 2 Nm
3.4
Mounting angle for SA167
Содержание BTL5-A11-M Series