OUT
A
M1
M2
Dig1
Dig2
Dig3
Dig4
+
SET
-
0
4
5
0
-
This operation is necessary when objects, inside the operating area, must not be detected.
-
Detection of the reflecting tape characteristics
-
Press contemporily the + and
– push-buttons for at least 6s.
-
The “TAPE” message appears.
OUT
A
M1
M2
Dig1
Dig2
Dig3
Dig4
+
SET
-
t
A
p
E
t
A
p
E
-
The reflecting tape characteristics are memorised when the push-buttons are released (the
“TAPE” message blinks for 2s, 4Hz) and the sensor returns to the normal mode.
OUT
A
M1
M2
Dig1
Dig2
Dig3
Dig4
+
SET
-
0
4
5
0
This operation is particularly suggested in the “AREA” operating mode as this mode is very sensitive
to the reflecting tape characteristics.
REMOTE FUNCTIONS
KEYLOCK
The keyboard block function is activated at powering on, connecting the SYNC terminal to the
positive power supply (+Vdc) for at least 1 s, and the push-buttons are NO LONGER active.
After the first second, the SYNC input is ready for the normal functioning and if the SYNC is passive
the outputs are deactivated.
To deactivate the
keyboard block
, the sensor has to be turned off and re-powered maintaining the
SYNC wire not connected or ground connected (GND).
SYNC input
The SYNC signal allows to determine precisely the beginning and end of the identification.
The identification cycle begins after the transition of the SYNC signal from passive to active and the
sensor outputs are updated after max. 8 ms.
All the outputs are deactivated after max. 8 ms from the active
– passive transition.
The connection of the SYNC wire to +Vdc corresponds to the passive logic status while SYNC not
connected or connected to 0 V corresponds to the active.
If the SYNC input is active, at the receipt of the
@ <CR> <LF>
command, the sensor responds
with:
?? <CR> <LF>.
At the receipt of the
q <CR> <LF>
or
e <CR> <LF>
commands, the sensor
transmits
ok <CR> <LF>.
NOTE: the single characters have to be distanced amongst themselves at least 1 ms, during
the command transmission.
DETECTION DIAGRAMS
DECLARATION OF CONFORMITY
We BALLUFF declare under our sole responsibility that these products are conform to the 89/336
CEE, 73/23 CEE Directives and successive amendments.
BALLUFF warrants its products to be free from defects.
BALLUFF will repair or replace, free of charge, any product found to be defective during the warranty
period of 24 months from the manufacturing date.
This warranty does not cover damage or liability deriving from the improper application of BALLUFF
products.
BALLUFF GmbH
Schurwaldstrasse 9
73765 Neuhausen a.d.F.
Germany
T49 (0) 71 58/1 73-0
T49 (0) 71 58/50 10
E-Mail:
Nr./No. 840 702D/E
Ausgabe/Edition H16;
Änderungen vorbehalten/Subject to modification
Ersetzt/Replaces 0506