background image

Balluff Network Interface 
BNI TCP-952-000-E029

                                                                               

Industrial Ethernet Switch

 

 

www.balluff.com                                                                                                                                                                                                                                     

1

 

This quick start guide describes how to install and use the Industrial Ethernet Switch. 
This is the switch of choice for harsh environments constrained by space. 

 

Physical Description 

The Port Status LEDs 

 

 

 

LED 

State 

Indication 

 

Power 1, 2 (Green) 

Steady 

Power on. 

Off 

Power off. 

 

Fault (Red) 

Steady 

Relay starts alarm. 

Off 

Relay non-alarm. 

Ports 

 

Link/ACT (Green) 

Steady 

A valid network connection established. 

Blinking 

Transmitting or receiving data. 

ACT stands for Activity. 

Off 

No link. 

 

 

The Terminal Block and Power Inputs 

 

Power Input Assignment 

Power 1 

 

12~48VDC 

Terminal Block 

 

Power Ground 

Power 2 

 

12~48VDC 

 

Power Ground 

 

Earth Ground 

Relay Output Rating 

1A @ 250VAC 

 
DC Terminal Block Power Input: The DC Terminal Block power input can be used to 
power up this Switch. 
 

DIP Switch Settings 

 

 

DIP No.  On 

Off 

Port 1 Alarm Enable. 

Port 1 Alarm Disable. 

Port 2 Alarm Enable. 

Port 2 Alarm Disable. 

Port 3 Alarm Enable. 

Port 3 Alarm Disable. 

Port 4 Alarm Enable. 

Port 4 Alarm Disable. 

Port 5 Alarm Enable. 

Port 5 Alarm Disable. 

Port 6 Alarm Enable. 

Port 6 Alarm Disable. 

Port 7 Alarm Enable. 

Port 7 Alarm Disable. 

Port 8 Alarm Enable. 

Port 8 Alarm Disable. 

Broadcast Storm Protection Enable.  Broadcast Storm Protection Disable. 

10 

Reserved 

 