Balluff Network Interface
BNI TCP-952-000-E029
Industrial Ethernet Switch
www.balluff.com
1
This quick start guide describes how to install and use the Industrial Ethernet Switch.
This is the switch of choice for harsh environments constrained by space.
Physical Description
The Port Status LEDs
LED
State
Indication
Power 1, 2 (Green)
Steady
Power on.
Off
Power off.
Fault (Red)
Steady
Relay starts alarm.
Off
Relay non-alarm.
Ports
Link/ACT (Green)
Steady
A valid network connection established.
Blinking
Transmitting or receiving data.
ACT stands for Activity.
Off
No link.
The Terminal Block and Power Inputs
Power Input Assignment
Power 1
+
12~48VDC
Terminal Block
-
Power Ground
Power 2
+
12~48VDC
-
Power Ground
Earth Ground
Relay Output Rating
1A @ 250VAC
DC Terminal Block Power Input: The DC Terminal Block power input can be used to
power up this Switch.
DIP Switch Settings
DIP No. On
Off
1
Port 1 Alarm Enable.
Port 1 Alarm Disable.
2
Port 2 Alarm Enable.
Port 2 Alarm Disable.
3
Port 3 Alarm Enable.
Port 3 Alarm Disable.
4
Port 4 Alarm Enable.
Port 4 Alarm Disable.
5
Port 5 Alarm Enable.
Port 5 Alarm Disable.
6
Port 6 Alarm Enable.
Port 6 Alarm Disable.
7
Port 7 Alarm Enable.
Port 7 Alarm Disable.
8
Port 8 Alarm Enable.
Port 8 Alarm Disable.
9
Broadcast Storm Protection Enable. Broadcast Storm Protection Disable.
10
Reserved