Balluff BNI IOL-302-002-K006 Скачать руководство пользователя страница 4

Balluff Network Interface / IO-Link BNI IOL-302-002-K006 

 

www.balluff.com 

   

 

 

1

 

User Instructions 

1.1.

 

Structure of the 
Manual 

  The manual is organized so that the sections build on one another. 

Chapter 2: Basic safety information. 
…….. 

 

1.2.

 

Typographical 
Conventions 

 

The following typographical conventions are used in this manual. 

 

Enumerations 

  Enumerations are shown as a list with an en-dash. 

 

Entry 1. 

 

Entry 2. 

 

Actions 

  Action instructions are indicated by a preceding triangle. The result of an action is indicated 

by an arrow. 

 

Action instruction 1. 

 

Action result. 

 

Action instruction 2. 

 

Syntax 

 

Numbers: 

Decimal numbers are shown without additional indicators (e.g. 123), hexadecimal numbers 
are shown with the additional indicator

 hex

 

(e. g. 00

hex

).

 

 

Cross-references 

  Cross-references indicate where additional information on the topic can be found. 

 

1.3.

 

Symbols 

 

Attention! 

This symbol indicates a safety instruction that must be followed without exception. 

 

 

 

Note 

This symbol indicates general notes. 

 

1.4.

 

 Abbreviations 

  BNI 

DPP 
I/O port 
IOL 
ISDU 
EMC 
FE 
LSB 
MSB 

Balluff Network Interface 
Direct Parameter Page 
Digital input/output port 
IO-Link 
Indexed Service Data Unit 
Electromagnetic compatibility 
Function earth 
Least Significant Bit 
Most Significant Bit 

 

1.5.

 

Divergent views 

  Product views and images can differ from the specified product in this manual. They serve 

only as an illustration. 

 
 
 

Содержание BNI IOL-302-002-K006

Страница 1: ...BNI IOL 302 002 K006 IO Link 1 1 sensor actuator hub with extension port User s Guide...

Страница 2: ...4 2 Process Data Input Data 10 4 3 Process Data Output Data 10 4 4 Parameter Data Demand Data 11 Inversion of the inputs 40hex 12 Configuration of inputs outputs 41hex 12 Safe state of outputs 42hex 1...

Страница 3: ...ts on Pin 2 43hex 32 Voltage monitoring 44hex 33 Monitoring the outputs 45hex 34 Actuator warning 46hex 34 Setting the serial number 54hex 35 Configuration of the extension port 55hex 35 6 5 Error Cod...

Страница 4: ...bers Decimal numbers are shown without additional indicators e g 123 hexadecimal numbers are shown with the additional indicator hex e g 00hex Cross references Cross references indicate where addition...

Страница 5: ...uthorized tampering Improper use Use installation or handling contrary to the instructions provided in this user s guide Obligations of the operating company The device is a piece of equipment in acco...

Страница 6: ...rd I O port 3 5 Status LED Standard I O port 5 pin 2 6 Standard I O port 5 7 Status LED Standard I O port 5 pin 4 8 Extension port or standard I O port 7 9 Status LED Power supply for sensors 10 Stand...

Страница 7: ...on ground The modules are equipped with a ground connection Figure 3 3 BNI ground connection IOL 302 Connect the sensor hub module to the ground connection Note The FE connection from the housing to t...

Страница 8: ...uts outputs freely configurable Digital sensors Digital input output port M12 A coded female Pin Requirement 1 24 V 2 Input 2 output 2 3 0 V GND 4 Input 1 output 1 5 FE Note For the digital inputs the...

Страница 9: ...of 55hex This makes it possible to operate one of the following modules using the No 7 slot BNI IOL 302 002 K006 BNI IOL 751 V08 K007 BNI IOL 751 V10 K007 BNI IOL 751 V13 K007 Extension port configur...

Страница 10: ...ort 3 Pin 4 Input Port 2 Pin 4 Input Port 1 Pin 4 Input Port 0 Pin 4 Input Port 7 Pin 2 Input Port 6 Pin 2 Input Port 5 Pin 2 Input Port 4 Pin 2 Input Port 3 Pin 2 Input Port 2 Pin 2 Input Port 1 Pin...

Страница 11: ...umber 16 bytes 0hex 16hex 0 Hardware revision 17hex 0 Firmware revision 18hex 0 Application specific tag 32 bytes 0hex DPP ISDU Parameter Data width Access rights Default Value Index Index Subindex Pa...

Страница 12: ...n 2 Inversion of Port 4 Pin 2 Inversion of Port 3 Pin 2 Inversion of Port 2 Pin 2 Inversion of Port 1 Pin 2 Inversion of Port 0 Pin 2 Inversion of port x 0 Normal 1 Inverted Configuration of inputs ou...

Страница 13: ...has not been set by the master then each output adopts the configured status The following statuses can be configured for each pin Safe state of the outputs on Pin 4 42hex Byte 0 1 Bit 7 6 5 4 3 2 1...

Страница 14: ...2 1 0 7 6 5 4 3 2 1 0 Sub index 4 3 2 1 8 7 6 5 Description Safe state Port 3 Pin 2 Safe state Port 2 Pin 2 Safe state Port 1 Pin 2 Safe state Port 0 Pin 2 Safe state Port 7 Pin 2 Safe state Port 6 P...

Страница 15: ...rcuit Port 5 Pin 4 Short circuit Port 4 Pin 4 Short circuit Port 3 Pin 4 Short circuit Port 2 Pin 4 Short circuit Port 1 Pin 4 Short circuit Port 0 Pin 4 Short circuit Port 7 Pin 2 Short circuit Port...

Страница 16: ...this parameter This prevents a device from connecting to the wrong master port Configuration of the extension port 55hex Configuration Index 55hex value BNI IOL 302 002 K006 0 BNI IOL 302 002 K006 wi...

Страница 17: ...put Port 4 pin 4 Input Port 3 pin 4 Input Port 2 pin 4 Input Port 1 pin 4 Input Port 0 pin 4 Extension Port Validation state Input Port 6 pin 2 Input Port 5 pin 2 Input Port 4 pin 2 Input Port 3 pin 2...

Страница 18: ...in 4 Output Port 0 Pin 4 Output Port 6 Pin 2 Output Port 5 Pin 2 Output Port 4 Pin 2 Output Port 3 Pin 2 Output Port 2 Pin 2 Output Port 1 Pin 2 Output Port 0 Pin 2 Byte 2 3 Bit 7 6 5 4 3 2 1 0 7 6 5...

Страница 19: ...en with Sensor Actor hub M12 15hex 0 Serial number 16 bytes 0hex 16hex 0 Hardware revision 17hex 0 Firmware revision 18hex 0 Application specific tag 32 bytes 0hex DPP ISDU Parameter Data width Access...

Страница 20: ...of Port 4 Pin 2 Inversion of Port 3 Pin 2 Inversion of Port 2 Pin 2 Inversion of Port 1 Pin 2 Inversion of Port 0 Pin 2 Byte 2 3 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Sub index 24 23 22 21 20 19 18 17 3...

Страница 21: ...4 Pin 2 Direction Port 3 Pin 2 Direction Port 2 Pin 2 Direction Port 1 Pin 2 Direction Port 0 Pin 2 Byte 2 3 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Sub index 24 23 22 21 20 19 18 17 32 31 30 29 28 27 26...

Страница 22: ...es can be configured for each pin Safe state of the outputs on Pin 4 42hex Byte 0 1 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Sub index 4 3 2 1 8 7 6 5 Description Safe state Port 3 Pin 4 Safe state Port 2...

Страница 23: ...2 Safe state Port 6 Pin 2 Safe state Port 5 Pin 2 Safe state Port 4 Pin 2 Byte 2 3 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Sub index 12 11 10 9 16 15 14 13 Extension port Description Safe state Port 3 Pi...

Страница 24: ...ription Short circuit Port 7 Pin 1 Short circuit Port 6 Pin 1 Short circuit Port 5 Pin 1 Short circuit Port 4 Pin 1 Short circuit Port 3 Pin 1 Short circuit Port 2 Pin 1 Short circuit Port 1 Pin 1 Sho...

Страница 25: ...0 1 Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 Sub index 8 7 6 5 4 3 2 1 16 15 14 13 12 11 10 9 Description Warning Port 6 Pin 4 Warning Port 5 Pin 4 Warning Port 4 Pin 4 Warning Port 3 Pin 4 Warning Port 2...

Страница 26: ...set using this parameter This prevents a device from connecting to the wrong master port Configuration of the Extension port 55hex Configuration Index 55hex value BNI IOL 302 002 K006 0 BNI IOL 302 0...

Страница 27: ...t 5 Pin 4 Input Port 4 Pin 4 Input Port 3 Pin 4 Input Port 2 Pin 4 Input Port 1 Pin 4 Input Port 0 Pin 4 Extension Port Validation state Input Port 6 Pin 2 Input Port 5 Pin 2 Input Port 4 Pin 2 Input...

Страница 28: ...lve 11 Coil A Valve 10 Coil A Valve 09 Coil A Valve 08 Coil A Valve 07 Coil A Valve 06 Coil A Valve 05 Coil A Valve 04 Coil A Valve 03 Coil A Valve 02 Coil A Valve 01 Coil A No function for V013 Byte...

Страница 29: ...ensor Actor hub M12 extended with Valve plug CG25 24 2 3 Sensor Actor hub M12 extended with Valve plug CG13 24 2 3 Sensor Actor hub M12 extended with Valve plug CG22 23 22 2 3 15hex 0 Serial number 16...

Страница 30: ...rsion of Port 5 Pin 2 Inversion of Port 4 Pin 2 Inversion of Port 3 Pin 2 Inversion of Port 2 Pin 2 Inversion of Port 1 Pin 2 Inversion of Port 0 Pin 2 Inversion of port x 0 Normal 1 Inverted Configur...

Страница 31: ...2 1 0 7 6 5 4 3 2 1 0 Sub index 4 3 2 1 8 7 6 5 Description Safe state Port 3 Pin 4 Safe state Port 2 Pin 4 Safe state Port 1 Pin 4 Safe state Port 0 Pin 4 Safe state Port 6 Pin 4 Safe state Port 5 Pi...

Страница 32: ...22 20 18 16 14 12 10 Valve terminal on the extension port Description Valve 08 Coil B Valve 07 Coil B Valve 06 Coil B Valve 05 Coil B Valve 04 Coil B Valve 03 Coil B Valve 02 Coil B Valve 01 Coil B S...

Страница 33: ...Short circuit Port 7 Pin 1 Short circuit Port 6 Pin 1 Short circuit Port 5 Pin 1 Short circuit Port 4 Pin 1 Short circuit Port 3 Pin 1 Short circuit Port 2 Pin 1 Short circuit Port 1 Pin 1 Short circ...

Страница 34: ...19 17 Extension port Description Valve 12 Coil A Valve 11 Coil A Valve 10 Coil A Valve 09 Coil A Valve 08 Coil A Valve 07 Coil A Valve 06 Coil A Valve 05 Coil A Valve 04 Coil A Valve 03 Coil A Valve 0...

Страница 35: ...parameter This prevents a device from connecting to the wrong master port Configuration of the extension port 55hex Configuration Index 55hex value BNI IOL 302 002 K006 0 BNI IOL 302 002 K006 with BNI...

Страница 36: ...rrun 0x8035 Function not available 6 6 Events IO Link Revision 1 0 Event code Description 0x5112 Low sensor voltage US 0x5114 Low actuator voltage UA 0x5410 Output stages 0x8DF0 Retry at the extension...

Страница 37: ...tion is automatically transferred to the new device This guarantees minimal downtime Validation must be switched on in order to use the data storage For information about the configuration of data sto...

Страница 38: ...Dimension L W H without connector 115 50 30 8 mm 8 3 Electrical Data Supply voltage 18 30 2 V DC corresponding to EN 61131 2 Ripple 1 Current consumption without load 65 mA Load current PIN 1 Max 200...

Страница 39: ...ication Green negatively pulsed Communication OK Red Communication overload Off Module is without voltage US LED Green Sensor power supply is OK Green flashing quickly Undervoltage 18 V Off Module is...

Страница 40: ...t circuit actuator warning actuator short circuit Off Input output signal 0 Extension port The table is valid if the extension port is active If the extension port is used as a standard I O then the d...

Страница 41: ...302 002 K006 BNI007Z BNI IOL 302 002 K006 Balluff Network Interface IO Link interface Functions 302 16 inputs outputs Variants 002 with IO Link 1 1 extension port Mechanical configuration K006 plasti...

Страница 42: ...www balluff com Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de No 919408 726 E 04 130063 Edition G20 Replaces Edition I16 Subject...

Отзывы: