8
english
2
System integration (continued)
2.2
Integration
2.2.1 Address details
The following settings are assigned at the factory:
– IP address: 192.168.1.1
– Subnet mask: 255.255.255.0
– Gateway address: 192.168.1.1
2.2.2 Data configuration
Enter the values from Tab. 2-1 in the control system. They
describe the data sizes of the entry, output and
configuration data.
Data size
Instance ID
Length of data
INPUT
100
392
OUTPUT
101
262
CONFIG
102
194
Tab. 2-1: Data configuration
2.2.3 Configuration data
Tab. 2-2 shows an assignment of the configuration data
sequence. The stated standard values describe a
configuration with the IO-Link function on Pin 4 and
standard I/O functions on Pin 2 and 4 of every port. The
input and output functions of the configured standard I/O
ports are set using the process data.
Byte
Slot Module
part
Description
0…1
1
Module
General configuration for
the overall module
2…25
2
IO-Link
Port 0
Configuration of the
IO-Link Port 0
26…49
3
IO-Link
Port 1
Configuration of the
IO-Link Port 1
50…73
4
IO-Link
Port 2
Configuration of the
IO-Link Port 2
74…97
5
IO-Link
Port 3
Configuration of the
IO-Link Port 3
98…121
6
IO-Link
Port 4
Configuration of the
IO-Link Port 4
122…145
7
IO-Link
Port 5
Configuration of the
IO-Link Port 5
146…169
8
IO-Link
Port 6
Configuration of the
IO-Link Port 6
170…193
9
IO-Link
Port 7
Configuration of the
IO-Link Port 7
Tab. 2-2: Configuration data
Module configuration BNI EIP-508-105-Z067
Byte
Bit
Description
7 6 5 4 3 2 1 0
0
P3
P2
P1
P0
Port function 0x00:
Standard-I/O 0x01:
IO-Link
1
P7
P6
P5
P4
Tab. 2-3: Module configuration
IO-Link Port configuration
Byte
Bit
Description
7
6
5 4 3 2 1 0
2
Basis
Time
Cycle Time
3
Validation type
– 0: No validation
– 1: Compatible
(VID + DID)
– 2: Identical
(VID + DID +
SerNum)
4
Manufacturer code 1
Manufacturer
code
5
Manufacturer code 2
6
Device code 1
Device code
7
Device code 2
8
Device code 3
9
Serial number 1
Serial number
…
…
24
Serial number 16
25
Parameter server
– 0x8X Switch on
– 0x0X Switch off
– 0x40 Delete
– 0xX1 Switch on
upload
– 0xX2 Switch on
download
…
The data of the other IO-Link Ports are structured
identically and described below.
Tab. 2-4: IO-Link Port configuration
BNI EIP-508-105-Z067
Network interface
Содержание BNI EIP-508-105-Z067
Страница 1: ...deutsch Konfigurationsanleitung english Configuration Guide BNI EIP 508 105 Z067 ...
Страница 2: ...www balluff com ...
Страница 3: ...BNI EIP 508 105 Z067 Konfigurationsanleitung deutsch ...
Страница 4: ...www balluff com ...
Страница 45: ...BNI EIP 508 105 Z067 Configuration Guide english ...
Страница 46: ...www balluff com ...
Страница 87: ......