www.balluff.com
english
5
2.1
Function overview
– Parallel laser light band with an active width of 50 mm
– CCD technology permits simultaneous detection of
multiple edges
– Can be used even over large emitter-receiver distances
(recommended maximum distance: 2 m)
– Data output only via IO-Link
– Two independently usable analog modes
– Can be used for precision web edge guiding
– Simultaneous output of diameter and position of
objects
– Distinguishes up to 6 different objects
– Counting the objects in the light band
– Integrated display
2.2
Intended use
Installation
and
startup
may only be performed by
trained specialists with basic electrical knowledge.
Qualified personnel
are those who can recognize
possible hazards and institute the appropriate safety
measures due to their professional training, knowledge,
and experience as well as their understanding of the
relevant conditions pertaining to the work to be done.
The
operator
is responsible for ensuring that local safety
regulations are observed.
In particular the operator must take steps to ensure that a
defect in the Light Array is not able to result in hazards to
persons or damage to equipment.
When defects or non-clearable faults occur in the Light
Array, it should be taken out of service and secured
against unauthorized use.
2.3
Safety notes
– Read this user's guide carefully and in full before
starting up the device.
– These devices are not safety components as defined
by the EC Machinery Directive. They may not be used
when the safety of persons or machines depends on
the function of the device.
– Accident prevention regulations and local prevailing
legal provisions must be observed.
– Installation, connection and startup are to be perfor-
med only by specialized personnel. The Technical Data
must be observed!
– Do not look directly into the light source – risk of glare
and eye irritation! Install the sensor such that it is not
possible to look directly into the light source!
– Laser Class I according to DIN EN 60825-1
– Do not use in explosion hazard areas! Danger of
ignition!
– The devices must be protected against moisture and
contamination during hookup, startup and operation. In
particular keep the entrance and exit windows for the
light band clear.
– The devices must be continually protected against
mechanical effects such as impacts and vibration.
– The manufacturer is not liable for damages due to
faulty use. The manufacturer’s warranty shall be void if
a unit is opened.
– Take the Light Array out of service if a non-clearable
error should occur.
2.4
Explanation of the warnings
Always observe the warnings in these instructions and the
measures described to avoid hazards.
The warnings used here contain various signal words and
are structured as follows:
NOTICE!
Identifies a hazard that could
damage
or
destroy
the
product
.
DANGER
The general warning symbol in conjunction with the
signal word DANGER identifies a hazard which, if not
avoided, will certainly result in
death
or
serious injury
.
2.5
Disposal
This product is covered by WEEE Directive
2012/19/EN on waste electrical and electronic
equipment.
Dispose of the product properly and not as part of the
regular waste stream. The regulations of the respective
country are to be observed. Information is provided by the
national authorities.
2
Safety
BLA 50A-002-S4
Balluff Light Array
BLA 50A-002-S4
Содержание BLA 50A-002-S4
Страница 1: ...deutsch Betriebsanleitung english User s guide BLA 50A 002 S4 Balluff Light Array...
Страница 2: ...www balluff com...
Страница 3: ...deutsch BLA 50A 002 S4 Balluff Light Array Betriebsanleitung...
Страница 23: ...english BLA 50A 002 S4 Balluff Light Array User s Guide...
Страница 43: ......