www.balluff.com
BIS U-602_ Processor Unit
TCP/IP / RS232
11
Included in the scope of delivery:
– BIS U-602_
– 5x end cap
Note
Visit
for more information on available software and accessories.
29
8
31
2
107,6
20
20
54
59,8
M5
M5
88
Figure 2: Installation
Caution!
The antennas for the identification system BIS U transmit ultra-high frequency electro-
magnetic waves!
►
The installation position of the processor unit and antennas must guarantee a
safety distance between the antennas and the workplaces of personnel (for safety
distances,
).
The read/write distance can (typically) be as great as 6 m, depending on the ambient conditions
and installed system components. See the "Basic UHF manual" for more information on mini-
mum/maximum distances.
►
Select a suitable installation position.
►
Secure the processor unit using four M5 screws
(strength category 8.8, lightly oiled, tightening torque M = 5.2 Nm).
Note
Optional mounting plates are available for installing the processor unit (
)
.
4.1 Processor Unit
Scope of Delivery
4.2 Processor Unit
Installation
4
Installation
Содержание BIS U-6020-053-10 RS232