BIS U-602_ Processor Unit
TCP/IP / RS232
26
EPC length
Length of the EPC format on the data carriers. This parameter determines the byte length of the
address (16 or 62 bytes) in the read and write commands and the byte length of the data block
for EPC (12 or 62 bytes) in the detection, read and write commands.
Factory setting:
96 bits
Note
If the actual EPC length is greater than 96 bits, the value 496 bits is to be set. Other-
wise, the detection, read and write commands are not answered.
Filtering
If this parameter is active, data carriers with the same ID (EPC, TID or USER data) are grouped
together in a response for automatic reading during a data carrier search.
Factory setting:
Filtering off
7