48
english
6.1
Device Status and Detailed Device Status
6.1.1 Description
The
Device Status
feature provides information about the
current device status.
Each
Device Status
is combined with a corresponding
diagnostic message (
see section 3.6 on
page 18).
It also gives the user the possibility to actively read out
currently pending events of the device.
6.1.2 ISDU
Name
Index
Subindex
Access
Length
Data Type Data Storage
Default
Device Status
0x0024 (36)
0
R
1 byte
UINT8
n/a
–
Detailed Device Status
0x0025 (37)
0
R
30 bytes
–
n/a
–
Detailed Device Status
1…10
R
3 bytes
RECORD
n/a
0x00 0x00
0x00
Tab. 6-1: Device status and detailed device status – ISDU
6.1.3 Device Status
The parameters are accessed via subindex 0. The output
values are to be interpreted as follows:
Value
Status
Description
0
Device is operating properly.
Device working correctly.
1
Maintenance Required
Although the process data is valid, internal diagnoses show that
the device will soon lose its ability to function properly.
Maintenance is necessary.
2
Out-of-Specification
Although the process data is valid, internal diagnoses show that
the device is operating outside of its specified measuring range
or environmental conditions. The installation must be checked
for unintentional malfunctions.
3
Functional check
Process data is temporarily invalid due to intentional changes to
the device, e.g., parameterization or teaching-in.
4
Failure
Process data is invalid due to a malfunction of the device or its
peripheral devices. The device is not able to perform its
intended function. Re-configuration (resetting to factory settings)
can help. Otherwise, Balluff service must be contacted or the
device replaced.
Tab. 6-2: Device Status