18
english
3
Overview of IO-Link Data and Functions (continued)
3.6
Events
Event Code Event Type
Description
Device Status
0x4000
(16384)
Error
Temperature Fault – Overload
– The device is
operated outside of the device-specific temperature
limits. Risk of device damage.
4 – Failure
0x4210
(16912)
Warning
Device Temperature Overrun – Clear Heat Of Source
– Risk of device damage. The device is too hot.
►
Remove heat source, provide the device with
heat insulation if necessary.
2 – Out-of-Specification
0x4220
(16928)
Warning
Device Temperature Underrun – Insulate Device
–
Risk of device damage. The device is too cold.
►
Insulate the device.
2 – Out-of-Specification
0x5110
(20752)
Warning
Primary supply voltage exceeded
►
Check for deviations in the supply.
2 – Out-of-Specification
0x5111
(20753)
Warning
Primary supply voltage below minimum value
►
Check for deviations in the supply.
2 – Out-of-Specification
0x8CD0
(36048)
Warning
Inclination alarm
►
Check installation.
1 – Maintenance-Required
0x8CD1
(36049)
Warning
Vibration alarm
►
Check machine.
0 – Device is operating properly.
0x8CFF
(36095)
Warning
Low signal quality level
0 – Device is operating properly.
0x8D07
(36103)
Warning
The calculation of the basic statistics was stopped
automatically to avoid a buffer overflow.
0 – Device is operating properly.
0x8D0B
(36107)
Warning
Overload or short circuit at pin 2
►
Check wiring.
2 – Out-of-Specification
0x8D0E
(36110)
Notification
The time has elapsed. This event reports the timeout
of the minimum value/maximum value/average
calculation.
It does not report a timeout for the calculation of the
moving average because the timer repeats and it
does not indicate the end of the calculation.
0 – Device is operating properly.
0x8D10
(36112)
Warning
Device Temperature Upper Warning
– The set upper
temperature warning threshold has been exceeded.
0 – Device is operating properly.
0x8D13
(36115)
Warning
One or more extreme conditions present.
0 – Device is operating properly.
0x8D20
(36128)
Warning
Device Temperature Lower Warning
– The device
temperature has fallen below the set lower
temperature warning threshold.
0 – Device is operating properly.
0x8D22
(36130)
Warning
Warning limit for write cycles reached – maintenance
monitoring no longer guaranteed – for information
purposes only.
0 – Device is operating properly.
0x8D23
(36131)
Error
Write cycle limit reached – saving no longer ensured
– replacement recommended.
1 – Maintenance-Required
0x8D24
(36132)
Warning
Parameter write error – for information purposes
only.
0 – Device is operating properly.
0x8D25
(36133)
Error
Parameters not consistent – basic settings are used,
service required. Parameterization processes and
resets can no longer be performed.
4 – Failure
Tab. 3-8: Events – Overview