background image

www.balluff.com

Handheld Programmer
BIS L-87_

9

Getting Started

3

BIS L-873-1-
008-X-000

BIS L-870-1-
008-X-002

Fig. 6: Handheld Programmer BIS L-873-1-008-X-000

1

 

Read/write head for BIS L data carriers with round coil Ø < 20 mm

 

Active surface (frontside)

Fig. 7: Handheld Programmer BIS L-870-1-008-X-002

1

 

Read/write head for BIS L data carriers with round coil 

Ø > 20 mm

2

 Barcode 

scanner

3

 

Active surface (underside)

Содержание BIS L-87

Страница 1: ...english Handheld Programmer BIS L 87_ englis mer BIS Quick Guide ...

Страница 2: ...www balluff com ...

Страница 3: ...of the warning notes 6 Getting Started 7 3 1 Battery operation 7 3 2 Overview of WORKABOUT PRO C 8 3 3 COLD RESET or battery replacement 10 3 4 Turning the Handheld Programmer on off 10 3 5 Keyboard display and operating concept 10 3 6 Creating your own operating interface 10 3 7 Starting the RFID application 11 3 8 Operating menu overview 11 Basic knowledge 17 4 1 Function principle of Identifica...

Страница 4: ... by PSION Teklogix GmbH The present manual does not describe Startup operation and care of the Workabout Pro handheld computer Installation and operation of accessories and expansion devices Docking station and device interfaces This information is found in the manuals from PSION Teklogix GmbH on the enclosed CD The most current documentation can be found on the Internet at www psionteklogix com N...

Страница 5: ...where additional information on the topic can be found e g see Technical Data on page 29 Buttons are set in brackets e g Write Menu commands are joined with a greater than symbol e g Start Programs stands for the menu command Programs from the start menu Keys are set in angle brackets e g confirm by pressing Enter Attention This symbol indicates a safety instruction that must be followed Note tip ...

Страница 6: ... local prevailing safety regulations are observed When defects and non clearable faults in the Identification System occur take the system out of service and secure it against unauthorized use Attention Improper use charging disposal or replacement of the rechargeable battery may result in an explosion Replace the rechargeable batteries only with the same or a type recommended by the manufacturer ...

Страница 7: ...hen not in use Data in the Handheld Programmer are retained for at least 10 to 15 minutes while the battery is being replaced Note User data are by default saved in a RAM based folder The data in this RAM folder are lost if the main battery pack and backup battery pack are completely drained or if the device is cold started see also Cold Reset Section 3 3 on page 10 The safest place to store the d...

Страница 8: ...1 1 008 X 000 Fig 4 Handheld Programmer BIS L 870 1 008 X 000 1 Read write head for BIS L data carriers with round coil Ø 20 mm 2 Active surface underside Fig 5 Handheld Programmer BIS L 871 1 008 X 000 1 Read write head for BIS L 15_ XX data carriers 2 Active surface frontside Getting Started 3 ...

Страница 9: ... X 002 Fig 6 Handheld Programmer BIS L 873 1 008 X 000 1 Read write head for BIS L data carriers with round coil Ø 20 mm Active surface frontside Fig 7 Handheld Programmer BIS L 870 1 008 X 002 1 Read write head for BIS L data carriers with round coil Ø 20 mm 2 Barcode scanner 3 Active surface underside ...

Страница 10: ...Click on Next Click on Backup In the Perform the Operation window click on Finish1 Requirements Supply voltage is present battery pack used and charged device is in the docking station of power supply is connected Attention This is a Class A product When using this product indoors the device may cause RF interference requiring the user to take appropriate measures Hold down Enter for at least 1 se...

Страница 11: ... RFID depending on the WindowsCE version only the Windows Logo may appear as shown in Fig 8 instead of a Start button As an alternative start option doubleclick the link BIS L RFID on the desktop The application BIS L RFID is started The start screen is displayed Fig 8 Windows CE Desktop Fig 9 Balluff application start screen After the start screen the tab Settings is displayed Fig 10 Settings tab...

Страница 12: ...ess UID Format Setting the display format of the serial number The serial number can be displayed in Hex hexadecimal Dec decimal or ASCII format Continuous Read Continuous Read If this option is enabled read requests are carried out automatically at the set interval Open Reader Activating the read write head The read write head is activated with the settings made and the options are grayed out The...

Страница 13: ...rrier type Address Start address for reading or writing The start address can be entered or set using the spin box Length Number of bytes you want to read or write The number of bytes can be entered or set using the spin box Format Char Byte Hex Bin Selecting the display format for data The data which were read are displayed according to the selection made in the selection field Read Starts a read...

Страница 14: ...the Settings tab the option Use CRC Check is activated Clear Clears the data read so far from the display window Tap on a data line in the display window The entry field Edit data opens The data can be chan ged using the keyboard Confirm the change with OK The entry field is closed the changed data are displayed on the RW Data tab Fig 13 Example Editing data ...

Страница 15: ... Browser can be used to load or save files Fig 14 File Browser tab Open Opens the dialog Open file A saved file can be selected and opened The data are displayed on the RW Data tab Save Opens the dialog Save file as The data from the display field on the tab RW Data can be saved in a file ...

Страница 16: ...Handheld Programmer BIS L 87_ 16 Getting Started 3 About tab Display of the software version and manufacturer information Fig 15 About tab ...

Страница 17: ...ring In process equipment organization In warehousing for monitoring stock movement and levels In transporting and conveying In waste disposal for quantity based fee assessment Handheld Programmer BIS L 87_ Plastic housing Reading writing using built in antenna Power for system components provided by 3 7V lithium ion battery pack Editor function for editing data to be read or written Saving loadin...

Страница 18: ...ing the non active phase data carrier outside the read write head zone No user bytes are sacrificed for storing a check code Shorter read time page is read once Shorter write time no check code is written Data read from a data carrier can be saved under a file name or saved files can be loaded Note User data are by default saved in a RAM based folder The data in this RAM folder are lost if the mai...

Страница 19: ...a carrier transformation The CRC check is a procedure for determining a check value for data in order to be able to recognize transmission errors If the CRC check is activated an error message is sent when a CRC error is detected Initializing To use the CRC check the data carriers must be initialized see Initializing data carriers starting on page 24 If the data carrier does not contain the correc...

Страница 20: ...Handheld Programmer BIS L 87_ 20 Dimensions Fig 33 BIS L 870 1 008 X 000 dimensions in mm Fig 34 BIS L 871 1 008 X 000 dimensions in mm Fig 35 BIS L 873 1 008 X 000 dimensions in mm Technical Data 5 ...

Страница 21: ...head connection Built in antenna Charging socket 2 5 mm jack socket Operating voltage VS 3 7 V Current consumption Normal operation approx 300 mA Reading writing approx 450 mA Voltage and current supply Type 3 7 V Lithium Ion rechargeable Capacity 4000 mAh max charging voltage 5 V Charging current 0 9 A Charging time 5 h Battery lifeS see page 7 48 h Ambient temperature range 10 C 50 C EMC EN 6100...

Страница 22: ...ite head for data carriers BIS L 15_ XX 873 Portable reader with integrated read write head for data carriers with Ø 20 mm Interface 1 Bluetooth Software type 008 Balluff Software for BIS _ 87x Language X Multilingual Additional features 000 001 002 003 004 005 Standard With WLAN With 1D barcode scanner With 2D barcode matrix scanner With WLAN and 1D barcode scanner With WLAN and 2D barcode matrix...

Страница 23: ...023835 Color black Features Consisting of charger power supply with charge status indicator and charging cradle primary connector EURO UK US interchangeable included CE UL approvals Charge status indicator LED red Battery charged LED red flashing Battery charging Primary voltage Uprimary 100 240 VAC Secondary voltage Usec 6 VDC 5 Input frequency Fprimary 50 60 Hz Secondary current Isec 800 mA Ambi...

Страница 24: ...Balluff GmbH Schurwaldstraße 9 73765 Neuhausen a d F Germany Tel 49 7158 173 0 Fax 49 7158 5010 balluff balluff de No 865779 E Edition 1002 Subject to modification www balluff com www balluff com ...

Отзывы: