Balluff BIS L-405-033-00*-05-MU Скачать руководство пользователя страница 2

3

3

english

Contents

Safety Notes ............................................................................................................................... 4

Introduction BIS L-405 Identification System ........................................................................ 5/6

Application BIS L-405 Processor ......................................................................................... 7-12

CRC data check with BIS L-405-037-... Processor .......................................................... 13/14

Installation L-405 ................................................................................................................. 15/16

Installation L-405-...-001-... ..................................................................................................... 17

Installation L-405-...-002-... ..................................................................................................... 18

Installation L-405-...-003-... ..................................................................................................... 19

Installation L-405-...-004-... ..................................................................................................... 20

Installation ........................................................................................................................... 21/22

Reorienting and Rotating the Read Head ............................................................................... 23

Connection Diagrams ............................................................................................................... 24

Technical  Data .......................................................................................................................... 25

Ordering Information ................................................................................................................ 26

Appendix, ASCII Table ............................................................................................................. 27

BIS L-405-03_-00_-05-MU_834487_E_0709.p65

4

english

4

Safety Notes

BIS L-4_ _ processor together with the other BIS L system components comprise the Iden-
tification System and may only be used for this purpose in industrial applications corre-
sponding to Class A of the EMC Directive.

Installation and operation are permitted by trained specialists only. Unauthorized modifica-
tions and improper use will result in loss of the right to make warranty and liability claims.

When installing the processor, follow exactly the connection diagrams provided later in this
document. Take special care when connecting the processor to external controllers, espe-
cially with respect to the selection and polarity of the connections including the power
supply.

Only approved power supplies may be used. For specific information, see the Technical
Data section.

When deploying the identification system, all relevant safety regulations must be followed.
In particular, measures must be taken to ensure that any defect in the identification system
does not result in a hazard to persons or equipment.

This includes maintaining the permissible ambient conditions and regular inspection for
proper function of the identification system and all the associated components.

At the first sign that the identification system is not working properly, it should be taken
out of service and guarded against unauthorized use.

This document applies to the processor BIS L-405-03_-00_-05-MU (Software version V1.2
and higher).

Scope

Malfunction

Installation and
operation

Deployment and
inspection

Proper use and
operation

Содержание BIS L-405-033-00*-05-MU

Страница 1: ...0_ 05 MU Manual Deutsch bitte wenden BIS L 405 03_ 00_ 05 MU_834487_E_0709 p65 2 No 834 487 D E Edition 0709 Specifications subject to change Replaces edition 0605 Balluff GmbH Schurwaldstrasse 9 7376...

Страница 2: ...laims When installing the processor follow exactly the connection diagrams provided later in this document Take special care when connecting the processor to external controllers espe cially with resp...

Страница 3: ...unit It does not require line fed power and receives its energy from the integrated read head in the BIS L 405 identification system The read head continuously sends a carrier signal which supplies t...

Страница 4: ...data carrier is indicated by the TP signal The first data value is not output until the ADR input signal changes Each time ADR changes the value of the next address is given to the data outputs As an...

Страница 5: ...sponse to address change 15 ms t3 STR acknowledges ReStart finished 7 ms BIS L 405 03_ 00_ 05 MU_834487_E_0709 p65 10 english 10 Application BIS L 405 Processor Restart with no data carrier present If...

Страница 6: ...405 03_ 00_ 05 MU_834487_E_0709 p65 12 english 12 Application BIS L 405 Processor Wiring up to 8 BIS L 405 processors in parallel The data lines from up to 8 BIS L 405 processor can be connected in p...

Страница 7: ...used with the BIS L 405 033 processor because there is no CRC 16 check BIS L 405 03_ 00_ 05 MU_834487_E_0709 p65 14 english 14 tx t1 t1 t1 t1 t1 t2 t2 t2 t2 t2 CRC data check with BIS L 405 037 CRC er...

Страница 8: ...account the conveyor speed Distance between the data carriers in m 0 4 x conveyor speed in m s 0 25 m Example Conveyor speed 1 m s Distance 0 4 x 1 m s 0 25 m 0 65 m This is an approximation for the w...

Страница 9: ...t read distance mm Speed m s BIS L 100 05 15 0 45 BIS L 101 05 20 0 5 BIS L 102 05 27 5 0 72 BIS L 103 05 10 0 36 BIS L 405 03_ 00_ 05 MU_834487_E_0709 p65 18 english 18 BIS L 405 002 Installation Ins...

Страница 10: ...n BIS L 405 004 Specifications by data carrier BIS L 405 037 004 Specifications by data carrier BIS L 405 033 004 BIS L 405 004 Installation Specifications by data carrier installed in clear zone For...

Страница 11: ...GRAY ROSE ADR RED BLUE SHIELDING SHIELD n c YELLOW BROWN BIS L 405 03_ 00_ 05 MU_834487_E_0709 p65 22 english 22 BIS L 405 Installation When installing BIS L 405 and BIS L 503 remove the PG fitting In...

Страница 12: ...on Rotating the read head Read head modules are not interchangeable Active surface positions Read head base Screw Active surface Set screw BIS L405 module BIS L 503 mounting base Read head module BIS...

Страница 13: ...EMC Laboratory which is accredited by the DATech for Testing Electromagnetic Compatibility we have verified that Balluff products meet the EMC re quirements of the following Generic Standards EN 6100...

Страница 14: ...29 1D Ctrl GS 51 33 3 72 48 H 93 5D 114 72 r 8 08 Ctrl H BS 30 1E Ctrl RS 52 34 4 73 49 I 94 5E 115 73 s 9 09 Ctrl I HT 31 1F Ctrl _ US 53 35 5 74 4A J 95 5F _ 116 74 t 10 0A Ctrl J LF 32 20 SP 54 36...

Отзывы: