![Balluff BIS C-6002 Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/balluff/bis-c-6002/bis-c-6002_manual_3598426040.webp)
79
79
english
Head 2 Head 1
X1
X2
X3
1
2
3
4
5
6
7
8
Head 1
Head 2
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
S1
S2
X4
BIS C-6022-...-ST10
Interface Information / Wiring Diagrams
Wiring diagram for
BIS C-6022-...-ST10
processor
X1
, supply voltage, digital input, and
CT Present outputs
X2
, PROFIBUS output
X3
, PROFIBUS input
n.c. =
do not connect!
The ground connector should be connected to earth directly or through
a RC combination depending on the system (potential counterpoise).
When connecting the bus leads, make sure that the shield has proper
connection to connector housing.
Pin
Function
1
+Vs
2
CT Present 2
3
–Vs
4
+IN
5
CT Present 1
Pin
Function
1
DGND
2
A
3
n.c.
4
B
5
n.c.
6
VP
7
+24 V
8
GND
9
10 ... 12
n.c.
☞
1
2
3
4
X4
, Service interface
Pin
Function
1
n.c.
2
TxD
3
GND
4
RxD
Protection
ground PE
C60_2-019_818217_0806-e.p65
80
english
80
Head 2 Head 1
X1
X2
X3
1
2
3
4
5
6
7
8
Head 1
Head 2
19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
S1
S2
X4
BIS C-6022-...-ST14
Interface Information / Wiring Diagrams
Wiring diagram for
BIS C-6022-...-ST14
processor
X1
, supply voltage, digital input
n.c. =
do not connect!
The ground connector should be connected to earth directly or through
a RC combination depending on the system (potential counterpoise).
When connecting the bus leads, make sure that the shield has proper
connection to connector housing.
1
2
3
5
4
X2
, PROFIBUS
input (male)
1
2
3
5
4
X3
, PROFIBUS
output (female)
2
1
4
5
3
Pin
Function
1
VP
2
A
3
DGND
4
B
5
n.c.
Pin
Function
1
+Vs
2
–IN
3
–Vs
4
+IN
5
n.c.
Protection
ground PE
☞
1
2
3
4
X4
, Service interface
Pin
Function
1
n.c.
2
TxD
3
GND
4
RxD