background image

 
Operating Manual 
Inductive Positioning System BIP AD0-B014-01-EP02

  

No. 872877 EN E16 

 

 

 

1

 

 

          

 

          

Safety instructions 

 

This analog positioning system must not  
be used in applications in which the safety 
of persons is dependent on the function  
of the system (not a safety component in 

accordance with the EU Machinery Directive).  
Read this manual carefully before commissioning. 

                         

Function 

 

The system detects the position of the position encoder 
within the taught measuring range and outputs this 
position as a current signal in the range 

0…10V. Here, 

the red LED indicates that the value is outside of the 
measuring range. The green LED illuminates if the 
position encoder is located within the measuring range. 
Use the programming button to change the measuring 
range as well as measuring direction.  

(see "Programming" and "Characteristics")    

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Balluff GmbH 
Schurwaldstrasse 9 
73765 Neuhausen a.d.F. 
Germany 
Phone +49 7158 173-0 
Fax +49 7158 5010 
[email protected] 
   www.balluff.com 

 
 
 
 
 

 

Compact design 

 

Analog output - voltage (U)

 

 

Non-contact

 

 

High repeat accuracy

 

 

High temperature stability 

 

High linearity

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание BIP AD0-B014-01-EP02

Страница 1: ...rhalb des eingelernten Messbereiches und gibt diese als Spannungssignal im Bereich 0 10V aus Die rote LED signalisiert dabei das Verlassen des Messbereiches Die gr ne LED leuchtet wenn sich der Positi...

Страница 2: ...ssung des Messsignals durch das Einbaumaterial zu minimieren siehe Einbauskizze 1 2 Wird neben dem Positionsgeber noch ein weiteres Metallteil vom Sensor erkannt f hrt dies zu ung ltigen Messsignalen...

Страница 3: ...auftreten blinkt die rote LED langsam Nach 20s kehrt der Sensor in den zuvor programmierten bzw in den Auslieferungs zustand zur ck Um den Sensor in den Auslieferungszustand zur ck zu versetzen dr cke...

Страница 4: ...0 mA Kurzschlussschutz ja Vertauschungsm gl gesch tzt ja Verpolungssicher ja Mechanische Daten Werkstoff Geh use PA Anzugsdrehmoment 0 5 Nm Werkstoff aktive Fl che PA Anschlussart Kabel Werkstoff Kabe...

Страница 5: ...in the taught measuring range and outputs this position as a current signal in the range 0 10V Here the red LED indicates that the value is outside of the measuring range The green LED illuminates if...

Страница 6: ...the measurement signal by the installation material see installation diagrams 1 2 If in addition to the position encoder another metal part is detected by the sensor invalid measurement signals result...

Страница 7: ...curs during programming the red LED flashes slowly After 20s the sensor returns to the previously programmed state or the state of delivery To reset the sensor to the state of delivery press the progr...

Страница 8: ...st miswiring yes Polarity reversal protected yes Mechanical data Housing material PA Tightening torque 0 5 Nm Sensing face material PA Connection type Cable Cable jacket material PUR Cable diameter D...

Отзывы: