Model:
BF-IDM10
Operating Guide
RFID Reader
Setup and Operation
For operation of BF-IDM10 Readers a IO-Link Master device is needed. The Master is used as
gateway between higher level controllers and RFID Reader.
Status Indicators
The device will show its status using the 2 LEDs at the corners of the housing. In normal
operation state the meaning of these lights are as follows:
►
Green light "Power" indicates that the device is connected to the processor unit and ready to
operate.
►
Orange light "Tag present" indicates that a RFID tag has been detected in front of the
transceiver coil.
Electrical Data
Operating voltage (nominal)
+24 V DC
Current draw (at +8 V DC)
≤ 200 mA
Operating Frequency
13.56 MHz
Active principle
Magnetic field
Transmit power
Class 5
Mechanical Data
Housing Material
Metal / ABS-GF16 / PBT / PA12-GF30
Weight max.
400g
Ambient temperature
0…+70°C