Secondary Device Functions (continued)
5.10 Extreme Environment Status
5.10.1 Description
With the help of the
Extreme Environment Status
, the time
is recorded in which the device was exposed to extreme
conditions. In parameter
Lifetime Extreme Thresholds
, limit
values can be configured for the respective conditions.
Parameter
Lifetime Extreme Status
can be used to read
out the current status as well as the summed time. The
calculation is based on the features of temperature (see
chapter 5.11 on page 68), humidity (see chapter 5.14
on page 76) and vibration (see chapter 5.13 on
5.10.2 Mathematics/Algorithm
If one (or more) extreme conditions are met, the device
begins to record the time.
If the power supply is interrupted during this time,
the time counter can have an error of maximum
180 seconds.
5.10.3 Process Data
Object ID
Name
Description
Direction
0x0041 (65)
Lifetime Extreme
One or more extreme conditions present.
Input
0x0042 (66)
Lifetime Extreme Time
Combined total time in which the device was exposed to an
extreme condition.
Input
Tab. 5-44: Extreme environment status – Process data
5.10.4 ISDU
Name
Index
Subindex
Access
Length
Data Type
Data Storage
Default
Lifetime Extreme
Thresholds
0x00D0 (208)
0
R/W
8 byte
Yes
Threshold Vibration
1
R/W
4 byte
FLOAT32
No
100 mm/s
2
Upper Threshold
Temperature
2
R/W
2 bytes
INT16
No
100 °C
Lower Threshold
Temperature
3
R/W
2 bytes
INT16
No
−40 °C
Lifetime Extreme Status
0x00D1 (209)
0
R
5 byte
n/a
State
1
R
1 byte
UINT8(ENUM)
n/a
Time
2
R
4 byte
UINT32
n/a
Tab. 5-45: Extreme environment status – ISDU
For the internal humidity, it is not possible to
parameterize your own limit values.
BES M08EH1-L01C20B-S04G-L04 /BES M12E_1-L01C_0_-S04G-L04 /
BES M18EH1-L01C_ _ _-S04G-L04
Inductive sensors
Содержание BES M08EH1-L01C20B-S04G-L04
Страница 2: ...www balluff com ...
Страница 4: ...www balluff com ...
Страница 98: ......
Страница 100: ...www balluff com ...