5.3.4 ISDU
Name
Index
Subindex
Access
Length
Data Type
Data Storage
Default
Switching Speed
Monitoring
0x009B
(155)
0
R/W
12 byte
Yes
Input
1
R/W
2 bytes
UINT16(ENUM)
No
0
Mode
2
R/W
1 byte
UINT8(ENUM)
No
0
Speed Upper Limit High
3
R/W
2 bytes
UINT16
No
100
Speed Upper Limit Low
4
R/W
2 bytes
UINT16
No
85
Speed Lower Limit High
5
R/W
2 bytes
UINT16
No
65
Speed Lower Limit Low
6
R/W
2 bytes
UINT16
No
50
Startup Delay
7
R/W
1 byte
UINT8
No
0
Switching Speed Status
0x009C
(156)
0
R
3 byte
n/a
State
1
R
1 byte
UINT8(ENUM)
n/a
–
Value
2
R
2 bytes
UINT16
n/a
–
Tab. 5-10: Signal Speed Monitor – ISDU
Switching Speed Monitoring Input
With
Switching Speed Monitoring Input
, the internal binary
signal source can be selected.
Input
contains a list of the
internal binary signals.
Switching Speed Monitoring Mode
With
Switching Speed Monitoring Mode
, the current mode
of the counter function can be selected.
Value
Meaning
Description
0x00 (0) Deactivated
Deactivated
0x01 (1) Speed
Speed monitoring
Tab. 5-11: Signal Speed Monitoring – Speed Monitoring Mode
Speed Upper Limit High
In combination with
Speed Upper Limit Low
, it forms a
threshold value with hysteresis for the
too high
status.
Speed Upper Limit Low
In combination with
Speed Upper Limit High
, it forms a
threshold value with hysteresis for the
too high
status.
Speed Lower Limit High
In combination with
Speed Lower Limit Low
, it forms a
threshold value with hysteresis for the
too low
status.
Speed Lower Limit Low
In combination with
Speed Lower Limit High
, it forms a
threshold value with hysteresis for the
too low
status.
5
Secondary Device Functions (continued)
BES M08EH1-L01C20B-S04G-L04 /BES M12E_1-L01C_0_-S04G-L04 /
BES M18EH1-L01C_ _ _-S04G-L04
Inductive sensors