IO-Link interface (continued)
6.5
System commands
Different commands have been implemented in the BCM
which can be reached via the parameter SYSTEM
COMMAND on index 0x0002 (2), subindex 0x00 (0). If a
system command is transferred to the BCM, the command
triggers the desired action if permitted in the current
application state.
Command Name
Description
0x80 (128)
DEVICE RESET Performs a virtual restart
0x81 (129)
APPLICATION
RESET
Restarts all modules,
OPERATION HOURS
SINCE STARTUP is set
to 0, BOOT CYCLE
COUNTER parameters
are not increased and
IO-Link communication
is maintained
0x82 (130)
RESTORE
FACTORY
SETTINGS
Resets all configurations
to their factory settings
0xA5 (165)
MAINTENANCE
RESET
Resets the minimum
and maximum values of
all modules and
OPERATING HOURS
SINCE RESET and
BOOT CYCLE
COUNTER SINCE
RESET are set to 0
Tab. 6-22: System commands
6.6
Device commands
Like system commands, the BCM also supports device
commands. These are transferred to parameter DEVICE
COMMAND on index 0x0064 (100) subindex 0x00 (0) and
are 32 bits long. The BCM supports the commands shown
Command
Name
Description
0x0000000B
(11)
1)
RESET
DEVICE
TEMPERA-
TURE
Resets the minimum
and maximum values of
the device temperature
module
(index 0x0052 (82)
subindex 0x02 (2),
subindex 0x03 (3),
subindex 0x06 (6) and
subindex 0x07 (7))
0x0000000C
(12)
RESET
CONTACT
TEMPERA-
TURE
Resets the minimum
and maximum values of
the contact temperature
module
(index 0x2031 (8241)
subindex 0x02 (2),
subindex 0x03 (3),
subindex 0x06 (6) and
subindex 0x07 (7))
0x0000000D
(13)
1)
RESET
HUMIDITY
Resets the minimum
and maximum values of
the relative humidity
module
(index 0x2041 (8257)
subindex 0x02 (2),
subindex 0x03 (3),
subindex 0x06 (6) and
subindex 0x07 (7))
0x0000000E
(14)
1)
RESET
AMBIENT
PRESSURE
Resets the minimum
and maximum values of
the ambient pressure
module
(index 0x2049 (8265)
subindex 0x02 (2),
subindex 0x03 (3),
subindex 0x06 (6) and
subindex 0x07 (7))
0x00000020
(32)
START/STOP
PING
Activates or deactivates
the ping function
1)
only for BCM R15E-
002
-DI00-_ _ , _-S4
Tab. 6-23: Device commands
BCM R15E-00 _ -DI00-_ _ , _-S4
Condition Monitoring Sensor
Содержание BCM R15E-00 Series
Страница 1: ...BCM R15E 00_ DI00 _ _ _ S4 deutsch Betriebsanleitung english User s guide...
Страница 2: ...www balluff com...
Страница 3: ...BCM R15E 00_ DI00 _ _ _ S4 Betriebsanleitung deutsch...
Страница 4: ...www balluff com...
Страница 49: ...BCM R15E 00_ DI00 _ _ _ S4 User s Guide english...
Страница 50: ...www balluff com...
Страница 95: ......