background image

 
User's Guide 
Inductive Analog Sensor BAW M18MI2-UAC50B-BP05-002/004

  

Nr. 818914 DE/EN Edition B16 

 
 

 

 

3

 

  

BAW M18MI2-UAC50B-BP05-002/004

 

  

 

    

 

 

 

Savety Advisory 

 

This analog sensor is not intended for use 
where personal safety depends on proper 
device function (not a safety component 
per the EU Machine Directive). Read the 

user's guide carefully before startup.

 

 
 

Function 

 

Inductive, analog sensor including three additional 
switching outputs. 
The switching distance is programmable. 

 
 

Dimensions

 

 

 

 
 
 

Connections 

  

 
Typ -002 

Typ -004 

 

 

 

Fig. 1: Connection diagram 

 
 

 
Balluff GmbH 
Schurwaldstraße 9 
73765 Neuhausen a.d.F. 
Deutschland 
Tel. +49 7158 173-0 
Fax +49 7158 5010 
[email protected] 
   www.balluff.de 

••••

 

Analog output voltage (U) 

••••

 

3 switching outputs 

••••

 

Type -002 3x NO 

••••

 

Type -004 3x NC 

••••

 

Switching distance programmable 

••••

 

Flush mount 

••••

 

M18x1 

 
 
 
 
 
 

Programming switching outputs in Teach-in 

  

There are two ways to use teach-in programming 
a) Connect the sensor to the BES 516-4 programmer. A 
programming guide is included with the unit. 
b) Connect the Control input (C) through a switch to +. 
Follow the programming steps below. 
Caution! Check for proper wiring. The load circuits must 
not be short circuited so that the sensor can be 
programmmed. 
 
1  Install the sensor in the machine. 
2  Connect the Control input (C) through a switch to + 
 

(Fig. 1). 

3  Turn on programming mode: Hold the button down for 
 

at least 5 seconds. 

4  Bring the object to be detected (machine member 

etc.) to the desired switching position or to a defined 
point (e.g. 4 mm from the sensor) within the sensor's 

 

linearity range (Fig. 2). 

5  Save switching distance: Hold the button down for 2-4 
 

seconds. The first LED comes on. When the button is 

 

released the next switching output is automatically 

 

selected. The next LED flashes. 

6  Program switching outputs two and three as 
 

described under 4. and 5. above. If no more outputs 

 

are to be programmed, exit programming mode as 
follows: Press the button for max. two seconds so that 
the 3

rd

 output is selected. Pres the button again for 2 

 

seconds to return the sensor to operating mode. 

7  After programming is complete make the user-side 
 

electrical connections. In operating mode a fixed 

 

connection between the C input and ground is 

 

recommended. 

 

Check switching points 

 

Move the target object (machine member etc.) towards 
the sensor. When a switching point is reached, the 
associated LED must come on. 

 

 

 

 

 

 

 

 

 

Отзывы: