Balluff BAV MA-NC-00025-01 Скачать руководство пользователя страница 6

2

english

BAV MA-NC-00025-01

Condition Monitoring Toolkit Base Unit

Technical Data

General Features

Memory

8 GB eMMC

Ethernet connection

RJ45, 2 × 10/100 MBit/s

Micro SD card

Class 10, 128 GB tested

USB-Port

USB 2.0

EMV directive 2014/30/EU

EN 61000-6-1 

EN 61000-6-3

Ambient conditions

Ambient temperature

−20…+60 °C

Storage temperature

−20…+70 °C

Protection per IEC 60529

IP20

Electrical data

Operating voltage

25.5…30 V DC

Power consumption 

(without connected sensors) 

at 24 V

≤ 180 mA

Maximum total current

IO-Link device supply

2.4 A (0.5 A per output)

Entire system

3 A

Ripple

< 1 %

Clock frequency

≤ 1.8 GHz (A53 core) / 

400 MHz (M4 core)

Electrical connection

Power supply

2-pole Phoenix connector

IO-Link

M8, 4-pins, A-coded, female

Mechanical features

Weight

approx. 230 g

Written offer

This product contains software components that are 

licensed by the copyright holders as Free Software or 

Open Source Software under the GNU General Public 

License, version 2, or the GNU Lesser General Public 

License, version 2.1. You may receive the source code of 

these software components from Balluff GmbH on a data 

carrier of our choice, if you submit a request within three 

years after shipping of the product (delivery made by 

Balluff GmbH) to the following address:

Balluff GmbH

Open Source 

Schurwaldstrasse 9 

73765 Neuhausen a.d.F.

Please enter the following product data:
–  Name of the product

–  Serial number

–  Delivery date

A fee will be charged, which is no higher than the cost of 

physically performing source distribution.

Control and display elements

Pushbutton S1

Reset to factory settings:

 

Press and hold pushbutton S1 approx. 15 seconds 

until the PWR, L1 and L2 LEDs light up continuously.

 

All settings are deleted and reset to the factory 

settings.

Status-LEDs

LED Status

Function

PWR Off

No power supply

Green

Power supply available, the device is 

ready.

L1

Off

Without meaning 

Red

Reset to factory setting active. 

L2

Off

Without meaning 

Yellow

Reset to factory setting active. 

Port-LEDs

LED Status

Function

1

Off

State of the Input or Output Pin is 0.

Yellow

State of the Input or Output Pin is 1.

0

Green

IO-Link connection established.

Green 

flashing

No IO-Link communication.

Red 

flashing

Validation failed.

Port configuration
Diagnostic 

input

Input

Output

Input low

Short-circuit

Pin 1 and 3

Short-circuit

on output Pin

Short-circuit

Pin 1 and 3

Electrical connection

Power supply

M8 IO-Link connectors

1

3

2

4

M8, female, 4-pins 

(top view)

Pin

Signal

Pin Signal

1

+24 V DC

1

+24 V

2

GND (0 V)

2

not conneced

3

GND

4

IO-Link-Data

Cable length

For IO-Link operation, the maximum cable length between 

base unit and sensor is 20 meters.

The maximum length for the LAN cable is 30 meters.

Содержание BAV MA-NC-00025-01

Страница 1: ...BAV MA NC 00025 01 deutsch Betriebsanleitung english User s guide...

Страница 2: ...endung Das Produkt ist f r folgende Anwendungen und Bereiche nicht bestimmt und darf dort nicht eingesetzt werden in sicherheitsgerichteten Anwendungen in denen die Personensicherheit von der Ger tefu...

Страница 3: ...frage an folgende Adresse stellen Balluff GmbH Open Source Schurwaldstra e 9 73765 Neuhausen a d F Bitte geben Sie folgende Produktdaten an Name des Produkts Seriennummer Auslieferungsdatum Es wird ei...

Страница 4: ...10 1 bei Anschluss an LAN Port 1 bzw die zugewiesene IP Adresse bei Anschluss an Port 2 2 Mit dem Usernamen admin und dem mitgeliefertem Passwort anmelden Bei der erstmaligen Inbetriebnahme erscheint...

Страница 5: ...st the manufacturer Reasonably foreseeable misuse The product is not intended for the following applications and areas and may not be used there In safety oriented applications in which personal safet...

Страница 6: ...owing address Balluff GmbH Open Source Schurwaldstrasse 9 73765 Neuhausen a d F Please enter the following product data Name of the product Serial number Delivery date A fee will be charged which is n...

Страница 7: ...2 168 10 1 when connected to LAN Port 1 or the assigned IP address when connected to LAN Port 2 2 Login with the username admin and the provided password You will be prompted to change the password th...

Страница 8: ...ngshan Rd 8F Building A Yunding International Commercial Plaza 200125 Pudong Shanghai Phone 86 400 820 0016 Fax 86 400 920 2622 service cn balluff com cn DACH Service Center Germany Balluff GmbH Schur...

Отзывы: