background image

www.balluff.com

1

Nr

. 943947 DE ∙ E19; Änderungen vorbehalten.

No. 943947 EN ∙ E!); Subject to modification.

english

Intended use

The Configuration Tool is used in conjunction with the USB 

adapter for configuring magnetic encoder systems of type 

BML-S1G…, BML SL1… and BML BM1… . Flawless 

function in accordance with the specifications in the 

technical data is ensured only when using original Balluff 

accessories. Use of any other components will void the 

warranty.

Non-approved use is not permitted and will result in the 

loss of warranty and liability claims against the 

manufacturer.

General safety notes

Installation and startup

 may only be performed by 

trained specialists.

The 

operator

 is responsible for ensuring that local safety 

regulations are observed. In particular, the operator must 

take steps to ensure that a defect in the position 

measuring system will not result in hazards to persons or 

equipment.

  DANGER

Uncontrolled system movement

When starting up, if the magnetic encoder system is part 
of a closed loop system whose parameters have not yet 
been set, the system may perform uncontrolled move-
ments. This could result in personal injury and equipment 
damage.

 

The system must be taken out of operation before 
configuration.

 

The sensor head may only be connected to the USB 
adapter for configuration.

 

After using the Configuration Tool remove the USB 
adapter. 

Function

The sensor head and sensor module are connected to the 

PC through the USB adapter.

The sensor head and sensor module can be configured on 

the PC using the BML Configuration Tool PC software. 

Using this tool you can read and write the BML parame-

ters, perform a calibration and display the position, signal 

quality and real-time errors.

Connecting the USB adapter

The USB adapter may not be connected to the 

PC when installing the configuration tool. It will 

be set up after the configuration tool is started 

for the first time.

Connecting the sensor head/sensor module using 

the USB adapter

:

1. 

Unplug connector from sensor head/sensor module.

2. 

Connect an appropriate cable to the USB adapter 

using a SUB-D9 female.

3. 

Connect cable to sensor head/sensor module using a 

corresponding plug.

Connecting the PC:
1. 

Connect the USB cable to the USB adapter.

2. 

Connect the USB cable to the PC.

Downloading further instructions

A detailed user’s guide for the sensor head/sensor module 

and the USB a Configuration Tool can be found on 

the Internet at 

www.balluff.com

 or requested by sending 

an e-mail from 

[email protected]

.

The CE Mark verifies that our products

meet the requirements of the current

EMC Directive.

BAE PD-ML-010-04

Configuration Tool + USB Adapter

Overview: Computer (with Configuration Tool), USB adap-

ter, and sensor head (example, computer and sensor head 

not included in the scope of delivery).

USB adapter

PC

USB cable

BML cable