IO-Link interface (continued)
6.7
Diagnostic data
The BTL reports diagnostic data to the controlling system
(see Tab. 6-10).
Event code
Characteristic
Meaning
0×8C10
Warning
Process variable range overrun - Process Data uncertain
The magnet is located below the specified measuring range or below the null
point. A process value is output but the data can exceed the linearity limits
specified in the data sheet.
0×8C20
Error
Measurement range overrun - Check application
The magnet is located outside of the measurable range and cannot be
detected. No valid data is output. The transferred process data value is
0×7FFFFFFC or 2147483644.
0×8C30
Warning
Process variable range underrun - Process Data uncertain
The magnet is located above the specified measuring range or above the end
point. A process data value is output. The data can exceed the linearity limits
specified in the data sheet.
0x8CA0
Warning
Magnet Number Change - temporary error state
The number of magnets was changed in FMM mode. For the duration of the
set diagnostic time, an error is output and the process data is marked as
invalid.
Tab. 6-10: Diagnostic data
BTL6-U101-M _ _ _ _ -PF-SA426-S4
Magnetostrictive Linear Position Sensor – Profile Style
Содержание BTL6-U101-M-Series-PF-SA426-S4
Страница 1: ...BTL6 U101 M_ _ _ _ PF SA426 S4 deutsch Betriebsanleitung english User s guide...
Страница 2: ...www balluff com...
Страница 3: ...BTL6 U101 M_ _ _ _ PF SA426 S4 Betriebsanleitung deutsch...
Страница 4: ...www balluff com...
Страница 27: ...BTL6 U101 M_ _ _ _ PF SA426 S4 User s Guide english...
Страница 28: ...www balluff com...
Страница 51: ......