6
6
.
.
C
C
O
O
N
N
T
T
R
R
O
O
L
L
M
M
O
O
D
D
E
E
L
L
Dehumidifying area II: The compressor stops for 5 minutes and operators for 5 minutes at the
lowest frequency.
Dehumidifying area III: The compressor stops.
6-3-10 Air Blowing mode
The outdoor unit does not work while the indoor fan runs with the fan speed selectable at the
auto, low, medium and high speeds.
When being auto, the fan speed is determined in the cooling mode (with the temperature
setting of 24
0
C in default).
The high, medium and low fan speeds are same with that in the cooling mode.
6-3-11 Compressor operating state indication
When the compressor is in operation, The 3 LED indicator lights on the control panel of
the outdoor unit indicates the causes of the restriction on the compressor’s current
operating frequency.
Symbols for indicator light::
★
: ON
Ο
: flashing
×
: OFF
LED1
LED2 LED3
The cause of the restriction on the compressor’s current
operating frequency
1
Ο
Ο
Ο
Normal frequency ascent and descent with no restriction
on the frequency
2
×
×
★
Frequency descent or restriction on frequency ascent
caused by over current
3
×
★
★
Frequency descent or restriction on frequency ascent
caused by anti-freeze in cooling or overload control in
heating
4
★
×
★
Frequency descent or restriction on frequency ascent
caused by too high compressor discharge temperature
5
×
★
×
Restriction on maximum operation operating frequency
caused by too low voltage on the supply circuit
6
★
★
★
Operating at a fixed frequency (when in a capacity
measurement or forced operation at a fixed frequency.)
8
★
×
×
Communication frequency drops.
6-3-12 Special notes
6-3-12-1 The outdoor unit of this model is electrified by the indoor unit control. After the system
24
BSGI
09(12)
Содержание BSGI 09
Страница 1: ...AS 09 12 UR4SVNVG SERVICE MANUAL XM00009562 1 2 3 4 2010 03...
Страница 3: ...9 2 Outdoor 41 10 PARTS LIST 45 10 1 Indoor 45 10 2 Outdoor 47...
Страница 14: ...5 5 E EL LE EC CT TR RI IC CA AL L D DA AT TA A 5 1 Electrical wiring diagrams 1 INDOOR 11 BSGI 09 12...
Страница 15: ...5 5 E EL LE EC CT TR RI IC CA AL L D DA AT TA A 12 2 OUTDOOR 5 2 Electric control 1 Indoor control BSGI 09 12...
Страница 16: ...5 5 E EL LE EC CT TR RI IC CA AL L D DA AT TA A 13 2 Outdoor control BSGI 09 12...
Страница 17: ...5 5 E EL LE EC CT TR RI IC CA AL L D DA AT TA A 14 OUT IPM BSGI 09 12...
Страница 18: ...5 5 E EL LE EC CT TR RI IC CA AL L D DA AT TA A 15 BSGI 09 12...
Страница 48: ...1 10 0 P PA AR RT TS S L LI IS ST T 10 1 Indoor 1 Parts 45 BSGI 09 12...