If the fire is on the fuel supply circuit, keep it closed and use the second circuit; if necessary
interconnect the burners.
•
If a fire occurs on a burner, do not reuse that burner.
•
Land as soon as possible.
•
If you do not succeed in putting out the fire, try using a fire resistant blanket; if this is not
within reach, use the envelope bag to put out the fire.
•
Prepare for a fast landing.
III.5
Gas leaks.
➢
On the ground:
•
Shut off the fuel supply.
•
Shut off the pilot lights.
•
Do not take off.
➢
During flight:
•
Shut off the fuel supply.
•
If the leak is on the fuel supply circuit, keep it closed and use the second circuit; if necessary
interconnect the burners.
•
If the leak occurs in one of the burners, keep the fuel supply circuit closed. Do not reuse this
burner.
•
In all cases, land as soon as possible.
III.6
Breakdown of a burner
III.6.1
Malfunction of one of the control valves
Switch over to the second circuit and use the other valve, taking care to close the first valve
properly.