background image

PLACEMENT INSTRUCTION

BALDR sensors are sensitive to surrounding 

environmental conditions. Proper placement of both the 

main unit and outdoor sensor are critical to the accuracy 

and performance of this product.

Main Unit Placement

Place main unit in a dry area free of dirt and dust. To help 
ensure an accurate indoor temperature measurement, be 
sure to place the Main unit away from heat sources or vents.

Outdoor Sensor Placement

Sensor must be placed outside to observe outdoor conditions. Sensor 
is water resistant for water splashes and is designed for general 
outdoor use, however, to extend its life place the sensor in an area 
protected from direct weather elements. The best location is 1.2 to 2.4 
meters (4 to 8 feet) above the ground with permanent shade and 
plenty of fresh air to circulate around the sensor.

Important Placement Guidelines

● The distance between main unit and transmitter should be at least 

   1.5~2 meters (5~6.5 feet) away from any interfering sources such 
   as computer monitors or TV sets.

● To maximize wireless range, place units away from large metallic 
    items, thick walls, metal surfaces, or other objects that may limit 

    wireless communication.

● Please do not use other electrical products such as headphones or 

   speakers operating on the same signal frequency.

● Neighbors using electrical devices operating on the same signal 

   frequency can also cause interference.

18

Содержание B0359WST2H2P

Страница 1: ...032 included Sensor by 2 x AA batteries not included We thank you for your purchase of Baldr wireless color weather station with temperature alerts It has been designed and constructed using innovativ...

Страница 2: ...orecast 2 Calendar display 3 Weekdays in 7 languages 4 Dual alarm function PRODUCT OVERVIEW MAIN UNIT 18 19 20 21 22 23 17 25 24 26 1 10 11 15 16 12 6 8 7 9 13 14 2 5 3 4 Weather forecast for next 12...

Страница 3: ...ty 10 Low battery indication 11 High low temperature warning 12 Indoor comfort level indication 13 Channel indication 14 Channel scan 15 Frost point warning 16 Barometric pressure 12 24 hour format se...

Страница 4: ...ded Please do not used as power supply If you need to replace the cell battery please take out the part device as shown in the figure below load new battery matching the polarity and THIS PRODUCT CONT...

Страница 5: ...evel indication Calendar alarm and snooze function Time display in 12 24H Frost point warning indication Temperature tendency display in arrows Weekdays in 7 languages GER German ENG English FRE Frenc...

Страница 6: ...x AA batteries in each sensor matching the polarity and 3 Replace the battery cover BALDR recommends high quality alkaline or lithium batteries for the best product performance Heavy duty or rechargea...

Страница 7: ...pecial note Press CH button on the main unit to set the channel The setting order is CH1 CH2 CH3 Channel scan from CH1 to CH2 to CH3 10 seconds intervals you must select the same number choices for bo...

Страница 8: ...o setting press SET button to skip setting steps or go to the next setting option Tips press and hold CH or button will quickly change the value by 8 steps 2 Press SET to select Weekday Language Defau...

Страница 9: ...D Date 8 Press SET to select the Month Press CH or button to adjust the value 9 Press SET to select the Date Press CH or button to adjust the value 10 Press SET to select 12 24H Time Format Default s...

Страница 10: ...n to save and exit setting 6 During setting if no operation for 20 seconds it will automatically save and exit setting 7 Alarm symbol will display on screen after setting 1 When the alarm is ringing p...

Страница 11: ...for temperature higher than 60 C the reading will be HH H 4 Arrow indication for temperature changes will display when temperature changes less than 1 C within one hour or compared with last reading...

Страница 12: ...perature Alert Indoor Low Temperature Alert Exit Default setting High Temperature Alert 35 C 95 F Low Temperature Alert 10 C 50 F 3 When in temperature alert display mode press ALERTS button to select...

Страница 13: ...ween 30 80 the accuracy is 5 if out of this range the accuracy will be 7 4 Arrow indication for humidity changes will display when humidity changes less than 5 RH within one hour or compared with last...

Страница 14: ...resolution 1 Tips The reading will be more accurate if it is placed at the same position for half an hour after power on When current outdoor channel s temperature is in the range of 0 C 2 9 C 32 F 3...

Страница 15: ...ding of the equipment you are more trusted or more used to you can manually calibrate the indoor temperature humidity and barometer values Calibrated value s reset method unplug the main unit power su...

Страница 16: ...ss communication such as TVs microwaves computers etc Problem Outdoor reading is flashing or showing dashes Flashing of the outdoor reading is generally an indication of wireless interference 1 Bring...

Страница 17: ...unit and sensor are placed out of direct sunlight and away from any heat sources or vents HH H LL L display in indoor and or outdoor temperature If your BALDR product does not operate properly after t...

Страница 18: ...end its life place the sensor in an area protected from direct weather elements The best location is 1 2 to 2 4 meters 4 to 8 feet above the ground with permanent shade and plenty of fresh air to circ...

Страница 19: ...ed to the carrier 3 damage to or deterioration of any accessory or decorative surface PRECAUTIONS Do not clean any part of the product with benzene thinner or other solvent chemicals When necessary cl...

Страница 20: ...oval from a fixed installation normal set up or adjustments claims based on misrepresentation by the seller or performance variations resulting from installation related circumstances To receive warra...

Отзывы: