Limitations: 

 
Baldor Generators is not responsible for the repair of generators required because of normal wear, accident, 
misuse, abuse, improper installation, lack of maintenance, unauthorized modifications or improper storage. 
 
Normal Wear: This warranty will not cover repair where normal use has exhausted the life of a part or 
generator.  It should be remembered that the service life of any generator is dependent on the care it 
receives and the conditions under which it has to operate. Some applications are very often used in dusty or 
dirty conditions, which can cause what appears to be excessive wear. Such wear, when caused by dirt, dust, 
grit or other abrasive material, which has entered the generator because of improper maintenance, is not 
covered by Warranty. 
 
 
 
For all product lines, the engine manufacturer warrants engine systems.  Contact Baldor Generators for 
current engine warranties. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

3815 Oregon Street • Oshkosh, Wisconsin 54902 

Phone: (920) 236-4200 • 800-872-7697 • Fax: (920) 236-4219 

www.baldor.com 

  

Revised\Effective 6/26/03 
Form # S-PSG-003-3 

 

                   Warranty Policy S-PSG-003-3.doc 

Содержание Premier 'K'

Страница 1: ...OPERATOR S MANUAL FOR YOUR PREMIER K SERIES GENERATOR BALDOR GENERATORS 3815 OREGON STREET OSHKOSH WI 54902 Phone 920 236 4200 Fax 920 236 4219 Toll Free 800 872 7697...

Страница 2: ...your generator set inspect it closely for shipping damage If you find some damage notify the transportation company immediately and file a freight damage claim Think of this manual as a tool to help...

Страница 3: ...es are not normally lethal an involuntary jerk of the hand caused by a hot surface or by an electrical shock can result in injury Repair of electrical generating equipment requires specialized skills...

Страница 4: ...le under the influence of alcohol drugs or medication When transporting or using a generator set with the wheel option secure the unit to prevent it from moving around Do not tamper with or change the...

Страница 5: ...RATOR SETS Operate the generator set on a level surface If the generator set is tilted fuel spillage may result Handle fuel with care It is highly flammable Use only clean properly marked and approved...

Страница 6: ...e generator set free of grass leaves and excessive grease and oils Allow the generator set to cool before transporting it or storing it indoors Have fire extinguisher accessible and nearby while opera...

Страница 7: ...tric Motor Loads 7 Parts and Service Information 8 Operation 9 Simple Troubleshooting 11 Control Panel for K3000 14 Control Panel for K5000 K5000E 15 Control Panel for K6500 K6500E 16 Wiring Diagram K...

Страница 8: ...All engines give off considerable heat when running Since the engine and your generator set uses air to keep it cool it is important that the temperature of the area in which it is located is does not...

Страница 9: ...r home where the building is also supplied electricity by a local utility shall be connected only by a competent electrician and only after the main service entrance switch has been disconnected and l...

Страница 10: ...on the hot surfaces Always shut the engine off and allow it to cool down before refueling it SPILLED FUEL MAY IGNITE AND CAUSE PROPERTY DAMAGE SEVERE INJURY OR EVEN DEATH IF IT WOULD COME INTO CONTAC...

Страница 11: ...Do not use sprayed water or compressed air to clean the generator set INSPECTING Inspect the external wires of the generator set for cuts fraying or loose connections Repair or replace any problems pr...

Страница 12: ...D SPARK PLUG SHOULD ALSO BE DISCONNECTED PRIOR TO PERFORMING MAINTENANCE This manual contains only very minimal engine maintenance instructions You should refer to the engine manufacturer s owner s ma...

Страница 13: ...nnect and remove the battery if your generator set is so equipped 3 Drain the used oil from the engine s crankcase and refill it with fresh clean oil if your engine is diesel proceed to step 4 4 If yo...

Страница 14: ...apacitor type motor or the split phase type motor The other factors that influence the amount of current needed to start a motor are 1 The type of load connected to the motor If the electric motor is...

Страница 15: ...r if known 4 Quantity of parts NOTE Engine parts can usually be obtained from a local representative of your engine manufacturer via the information in the engine manufacturer s Owner s Manual Baldor...

Страница 16: ...add if necessary NEVER REFUEL THE GENERATOR SET WHEN IT IS HOT OR RUNNING 5 Open the fuel valve on the fuel tank 6 If the engine is equipped with a fuel valve open it at this time 7 Check the fuel sy...

Страница 17: ...2 Either push the engine s start switch or turn the key switch fully clockwise to engage the electric start motor 3 Do not allow the starter motor to crank for more than 10 seconds at a time 4 Allow...

Страница 18: ...no output voltage Make sure the generator is turning at the speed on the nameplate 2 Broken wires or loose connections Broken wires or loose connections can cause the generator set to have low or no o...

Страница 19: ...attery across the capacitor longer than a fraction of a second may damage the windings of the generator Stop the unit after doing this and replace the end cover If you still have no output look for ot...

Страница 20: ...nor and the Auto Idler follow these steps A Turn the Auto Idler switch OFF and start the engine B Adjust the engine for the speed specified on the generator set s nameplate C Turn the Idler Switch ON...

Страница 21: ...level being produced by the generator set D CIRCUIT BREAKER This circuit breaker provides overload protection for the generator set When tripped the circuit breaker will switch to the Off position E...

Страница 22: ...running total of the hours accumulated on the unit C AC VOLTMETER This voltmeter displays the voltage level being produced by the generator set D AC CIRCUIT BREAKERS These circuit breakers provide ove...

Страница 23: ...ous running total of the hours accumulated on the unit C VOLTMETER This voltmeter displays the voltage level being produced by the generator set D AC CIRCUIT BREAKERS These circuit breakers provide ov...

Страница 24: ...K3000 Wiring Diagram 17...

Страница 25: ...K5000 Wiring Diagram 18...

Страница 26: ...K5000E Wiring Diagram 19...

Страница 27: ...K6500 Wiring Diagram 20...

Страница 28: ...K6500E Wiring Diagram 21...

Страница 29: ...Generator End Componentry 22...

Страница 30: ...CONTROL BOX COMPONENTRY 23...

Страница 31: ...meter X X X X X X EB1242A00 Idler Module X X X X X AA Duplex Receptacle Non GFCI BB WD1541A33SP Duplex Receptacle GFCI 250V 20 Amp CSA NEMA X X X X X CC WD1541A10 30A 125 VAC NEMA L530R Receptacle X X...

Страница 32: ...the reinstallation of the Baldor product upon its return to the party requiring warranty service Customers who are unable to take or ship the Baldor product to a Baldor Generator repair facility or wh...

Страница 33: ...ty Policy Warranty registration within 30 days of purchase is required for portable and towable products to qualify for any warranty consideration Proof of purchase date serial number and model number...

Страница 34: ...and the conditions under which it has to operate Some applications are very often used in dusty or dirty conditions which can cause what appears to be excessive wear Such wear when caused by dirt dust...

Страница 35: ...ia to cause cancer birth defects and other reproductive harm CALIFORNIA PROPOSITION 65 WARNING Diesel engine exhaust and some constituents are known to the state of California to cause cancer birth de...

Страница 36: ...Service is just a phone call away 800 872 7697 www baldor com products generators asp 3815 Oregon Street Oshkosh WI 54902 Phone 920 236 4200 Fax 920 236 4219...

Отзывы: