background image

(A42086) – Rev. B – 7/2000

V.  LIMITED WARRANTY

For a period of 2 years from date of original purchase, BALDOR will repair or replace without charge
controls which our examination proves to be defective in material or workmanship.  This warranty is
valid if the unit has not been tampered with by unauthorized persons, misused, abused, or improperly
installed and has been used in accordance with the instructions and/or ratings supplied.  This warran-
ty  is  in  lieu  of  any  other  warranty  or  guarantee  expressed  or  implied.    BALDOR  shall  not  be  held
responsible  for  any  expense  (including  installation  and  removal),  inconvenience,  or  consequential
damage, including injury to any person, caused by items of our manufacture or sale.  (Some states do
not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion
may not apply.)  In any event, BALDOR’s total liability, under all circumstances, shall not exceed the
full purchase price of the control.  Claims for purchase price refunds, repairs, or replacements must be
referred to BALDOR with all pertinent data as to the defect, the date purchased, the task performed by
the control, and the problem encountered.  No liability is assumed for expendable items such as fuses.

Goods  may  be  returned  only  with  written  notification  including  a  BALDOR  Return  Authorization
Number and any return shipments must be prepaid.

Baldor Electric Company

5711 R. S. Boreham, Jr. Street

Fort Smith, AR  72902-2400  U.S.A

(501) 646-4711  Fax (501) 648-5792

International Fax (501) 648-5895

Содержание BC145

Страница 1: ...SIGNAL ISOLATOR BC145 Signal Isolator Board Installation and Operating Manual 7 2000 MN1373...

Страница 2: ...15V Connection 5 2B 230V Connection 5 3 Current Input Signal Connection 6 4 Voltage Input Signal Connections 7 5A Leader Follower Voltage Following System with Multiple Motors 9 5B Leader Follower Vol...

Страница 3: ...d grounding can reduce the chance of electric shocks fires or explosion in this product or prod ucts used with this product such as electric motors switches coils solenoids and relays Eye protection m...

Страница 4: ...0 10V input For Regenerative Drives with bipolar 10V input other Signal Isolators are available A built in power supply enables the BC145 to be controlled with a 5K remote potentiometer connect potent...

Страница 5: ...IFICATIONS INCHES mm Illustrates Factory Setting of Jumpers and Approximate Trimpot Settings 3 1 MAX P1 VOLT CUR J1 MIN 2 3 4 5 6 7 8 9 10 4 mounting holes for 6 screws 2 244 57 0 0 276 7 00 0 276 7 0...

Страница 6: ...fications are based on an output of 10 volts AC Power Requirements 115 or 208 230V AC 50 60 Hz 1 Signal Input Voltage 2 0 25 0 120 0 550V DC Signal Input Current 2 1 5 4 20 10 50mA 3 Maximum Output Vo...

Страница 7: ...e AC line B Input Terminals A voltage or current signal from a microprocessor tachometer transducer etc is to be connected to terminals 5 through 8 The selection of the proper terminal is based on the...

Страница 8: ...by removing resistor R3 from the printed circuit board Recalibrate the Signal Isolator to follow a 4 20mA current signal input as follows 1 Connect a 10V DC meter digital DC meter is suggested to term...

Страница 9: ...re 4 1 Connect a 10V DC meter digital meter is suggested to terminals 9 and 10 2 Apply the maximum input voltage that would be supplied from tach transducer etc 3 Adjust the MAX trimpot to the desired...

Страница 10: ...n the maximum voltage 3 Trimpots allow approximately 20 turns for the full range of adjustment If during the adjust ment procedure the output stops changing try reversing the direction of rotation of...

Страница 11: ...nnect as above WARNING If Signal Isolator is connected to multiple speed controls 1 Multiple controls must be powered from the same phase of AC line 2 The positive input terminal to each speed control...

Страница 12: ...Auto Manual mode which will allow manual override of an automatic process See figure 6B FIGURE 6B PROCESS CONTROL WITH AUTO MANUAL SWITCH 9 10 BC145 5 7 90V DC Leader Motor A A BC141 BC141 Speed Pot...

Страница 13: ...t 10 9 P2 CONTROL BC145 The following circuit provides for dual pur pose usage of the speed pot In the AUTO mode it is used for ratio control and in the MAN mode it is used for manual speed adjust men...

Страница 14: ...any person caused by items of our manufacture or sale Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion may not apply In any event BAL...

Отзывы: