Balcrank Synergy 3110-019 Скачать руководство пользователя страница 3

Synergy – PC Interface Module 3110-019 

 
SERVICE BULLETIN SB 3075  Rev. A      3/12 

Balcrank Corporation, Inc. 

 

1. 

Introduction 

The PC Interface module is an accessory Synergy. With this, the system can be connected to a PC. It can also be 
used to amplify signals if the communication loop is more than 6500 feet (2000 meters). 

NOTE! 

The Synergy installation guide (SB3080) should be available when installing the module.

 

2. 

Mechanical installation 

The PC Interface module is delivered mounted in a box with a DSUB 9-pin serial cable. 

A module in a box is mounted on a wall or other suitable place close to a PC using the four 

ø

0.197” (

ø5 mm) holes 

in the bottom of the casing. The serial cable included is 10 ft. long (3 meters).  

3. 

Electrical installation 

The module has four connectors 

(A)

 in two groups. The four connectors are marked 

A

B

+24 V

 and 

Gnd

. Use 

these to connect the module to an existing system. Consult the cable recommendations in the Synergy installation 
guide (SB3080) 

NOTE! 

+24VDC may only be connected to one connector. 

At the connector 

(B)

 you connect the flat cable for RS-232 serial communication with a PC. Communication through 

this port is indicated by LED 

(C)

The LED 

(D)

 is lit when the system is working properly. 

If the module is used as a signal amplifier one communication loop should be connected to one Line and the other 
loop to the other Line. 

You must set termination and BIAS for BOTH groups using the DIL-switches at (E).

 

The PCB (Printed Circuit Board) gets its power from the communication loop. The circuit board takes power from 
the communication loop.If the module is placed far away from a MPDM it is possible to apply an external power-
supply to 

one

 of the connectors 

(A)

NOTE!  If only one line is used the other one must be terminated, all switches in the ON position. 

Отзывы: