Change Factory Settings

Changing the Batteries

The battery compartment is located in the lower case on the underside of the trigger guard .
1 .  Turn the unit face down .
2 .  Unscrew the two screws . Remove the battery door to expose the batteries .

Figure 11:  Replacing the batteries

3 .  Replace the old batteries . The meter takes four AA, alkaline, batteries . Battery polarity markings are inside the 

battery compartment .

4 .  Dispose of used batteries properly, according to local regulations .

OTEE:

N

Changing the batteries does not affect any of the programmed values or totals .

CHANGE FACTORY SETTINGS

Each meter is calibrated at the factory for use with motor oil . See 

"Change Scale Factor" on page 11

 The 

Unit of Measure

 is also 

selected prior to shipment .

Verify Firmware Version

The firmware version and code checksum are displayed by pressing and holding 

TOTAL

 and 

1

 simultaneously . The last two 

digits on the lower right are the firmware version . Meters with version 16 or higher use the procedure outlined in this manual 

for changing the unit of measure, scale factor and enabling or disabling the EPM functionality .

Programming

1 .  Press and hold 

TOTAL

 and 

AUTO

 simultaneously . PrG will appear on the display .

Figure 12:  Entering programming mode

2 .  Release the buttons .
3 .  Press and release these buttons in order: 

1

AUTO

10

0.1

, and 

TOTAL

 .

4 .  The current unit of measure will now be flashing indicating that you have entered the programming mode .

Page 10 

August 2015

Содержание 3331-028

Страница 1: ...________________ Electronic Preset Meter Model 3331 028 Thoroughly read and understand this manual before installing operating or servicing this equipment _____________________________________________...

Страница 2: ...de Functions 9 Re settable and Accumulated Totals 9 Emergency Override 9 Error Codes 9 Service 9 Low Battery 9 Changing the Batteries 10 Change Factory Settings 10 Verify Firmware Version 10 Programmi...

Страница 3: ...not modify or alter the equipment Do not leave equipment unattended while dispensing Check equipment daily Repair or replace worn or damaged parts immediately Do not exceed the maximum working pressu...

Страница 4: ...Auto Batch mode to clear the dispensed quantity and reset the meter for the next batch Used to reset the re settable total dispensed while pressing the TOTAL button Used to stop the flow through an Em...

Страница 5: ...mponents according to local state and federal codes Consult the pump user manual and other system components to ground the following Pump follow manufacturer s recommendations Air and Fluid Hoses use...

Страница 6: ...n ended adjustable wrench See Figure 4 Figure 4 Use wrench to tighten NOTE N The threaded end of the meter always has female threads The metal end of the hose must have male threads The inlet and outl...

Страница 7: ...nce to reset the counter display to zero Auto Batch Mode To enter Auto Batch Mode from Manual Mode press AUTO When in Auto Batch Mode the Auto icon displays and the batch quantity shows in the lower r...

Страница 8: ...English units See Change Unit of Measure on page 11 Emergency Override In case of an emergency or to interrupt a batch the meter is equipped with an Emergency Override which closes the valve immediat...

Страница 9: ...ry for use with motor oil See Change Scale Factor on page 11 The Unit of Measure is also selected prior to shipment Verify Firmware Version The firmware version and code checksum are displayed by pres...

Страница 10: ...SETTABLE TOTAL AND ACCUMULATED TOTAL Change Scale Factor CHANGING THE SCALE FACTOR CHANGES THE ACCURACY OF THE METER POTENTIALLY CAUSING IT TO OVERFILL OR UNDER FILL THIS HAS THE POTENTIAL TO CAUSE A...

Страница 11: ...d after field installation Use the Scale Factor showing on the display not on the trigger CHANGING THE SCALE FACTOR WILL CHANGE THE ACCURACY OF THE METER POTENTIALLY CAUSING IT TO OVERFILL OR UNDER FI...

Страница 12: ...Fluid Viscosity Scale Factor Water anti freeze 5 1 044 Anti freeze 18 1 007 Brake Fluid 42 1 004 ATF 80 1 002 10W 140 1 000 80W 90 450 0 999 140W 1800 0 993 Table 3 Fluid viscosity and scale factor D...

Страница 13: ...m 20 F 5 C Accuracy general 0 5 Accuracy anti freeze 1 5 5 digit LCD display Quarts Pints Gallons Liters Inlet and outlet connections 1 2 NPT 1 2 BSPP Minimum and maximum flow range will vary with flu...

Страница 14: ...024 Not shown Swivel NPT special fluids 64082 001 Not shown Rubber boot 65546 001 Table 6 Part numbers front of meter 1 2 3 Figure 19 Parts inside meter Item Description Part Number 1 Valve assembly...

Страница 15: ...connection press RESET Batteries dead Replace batteries press RESET Meter does not latch for batching Meter not in Auto Mode Press AUTO and program the batch size Meter not reset after prior batch Pr...

Страница 16: ...ision Log Rev A Release Balcrank Corporation Weaverville NC 28787 800 747 5300 800 763 0840 Fax www balcrank com SERVICE BULLETIN SB3109 Revision A 10 2016 For Warranty Information Visit www balcrank...

Отзывы: