background image

Page 9

Temperature Limitations

Sound Level Ratings

Moving Parts Hazard

Fire or Explosion Hazard

Static electricity can be created by the flow of fluid
through the pump or by the reciprocating action of
A.O.D. pumps. If the pump is not properly grounded,
sparking may occur and the system may become
hazardous. Sparks can ignite fumes or vapor and
cause an explosion.

If you experience static sparking or even a slight shock
while using the pump, do not continue to operate the
pump until the pump is properly grounded.

Proper Grounding

To ground metallic pumps, connect a ground wire 
to any accessible point of attachment such as a 
connecting bolt or the mounting base.

The diaphragm plates (sometimes referred to as 
piston plates) located inside the pump on either side
of the main shaft move when air pressure is supplied
to the pump. Therefore, never attempt to operate the
pump with the liquid chambers removed. Moving
parts inside the pump can pinch or seriously injure
fingers or other body parts.

1/2" Plastic pumps (Model 1120-011) have a 
maximum decibel reading of 89.5 dB(A) when
equipped with a factory installed air exhaust muffler.

The decibel readings are obtained with a Pacer
Industries model SL-120, sound level indicator “A”
scale. Readings are made at a distance of 1 meter
from the pump and at a height of 1.6 meters above
the floor. It is assumed that the pumps will be
installed at floor level.

Maximum temperature limitations are based on 
mechanical stress only. Certain chemicals will reduce
the maximum safe operating temperature of A.O.D.
pumps. Consult your dealer or Chemical Resistance
Guide for compatibility and temperature limits.

Polypropylene: 0°C (32°F) to 79°C (175°F)
Kynar: -12°C (10°F) to 107°C (225°F)

Do NOT exceed the maximum temperature limits of
the elastomer type (diaphragms, balls, seats) that are
used in the pump.

Temperature Limits of Various Elastomer Types:

Neoprene: -18˚C (0˚F) to 93˚C (200˚F)
Buna-N: -12˚C (10˚F) to 82˚C (180˚F)
Nordel: -51˚C (-60˚F) to 138˚C (280˚F) 
Viton®: -40˚C (-40˚F) to 176˚C (350˚F)
PTFE: 4˚C (40˚F) to 105˚C (220˚F)
Polyurethane: -12˚C (10˚F) to 77˚C (170˚F)
Santoprene: -29˚C (-20˚F) to 149˚C (300˚F)
FDA Hytrel®: -29˚C (-20˚F) to 104˚C (220˚F)

REVISION LOG

SERVICE BULLETIN SB 1060
5/03 Original Release 
7/07 Rev.1

Содержание 1120-011

Страница 1: ...C PUMP Model 1120 011 SERVICE BULLETIN SB 1060 Revised 7 07 OPERATION INSTALLATION MAINTENANCE AND REPAIR GUIDE Thoroughly read and understand this manual before installing operating or servicing this...

Страница 2: ...bility of the purchaser to retain this manual for reference Failure to comply with the recommen dations stated in this manual will damage the pump and void factory warranty In the presence of explosiv...

Страница 3: ...le Flow Rate Buna N Diaphragms 0 14 gpm 0 56 lpm Pump Connections Suction Discharge 1 2 NPT ID Air Inlet 0 375 NPT Air Exhaust 0 375 NPT Suction Lift Buna N Diaphragms 20 6 09m Dry Acetal Valve Balls...

Страница 4: ...bottom of the chart and move vertically until you cross the necessary air supply pressure Finally move horizontally to the left to find the required air supply volume 1120 011 Plastic Pump Performanc...

Страница 5: ...diaphragm in turn applies pressure on the fluid and forces it out of the pump discharge While this is occurring the opposite air chamber is depressurized and exhausted to atmosphere and fluid is drawn...

Страница 6: ...allation has the pump datum line below the fluid level IMPORTANT in flooded suc tion installations the pressure at the fluid inlet of the pump should never exceed 69 kPa 10 psi In suction lift install...

Страница 7: ...Snap Ring 2 17 Pilot Shaft Spacer 5 18 Shaft Retainer 2 393776 46 19 Pilot Retainer Screw 4 393776 47 20 Inner Diaphragm Plate 2 393776 155 21 Outer Diaphragm Plate 2 393776 110 22 Air Exhaust Muffler...

Страница 8: ...and valve housings are not designed to support any structural weight and failure of the pump may result The use of flexible piping connections is highly recommended Do NOT exceed the recommended opera...

Страница 9: ...c pumps Model 1120 011 have a maximum decibel reading of 89 5 dB A when equipped with a factory installed air exhaust muffler The decibel readings are obtained with a Pacer Industries model SL 120 sou...

Страница 10: ...r replacement of parts or products resulting from general wear and through use or damage or failure caused by improper installation abuse misapplication abrasion corrosion insufficient or improper mai...

Отзывы: